Literature DB >> 18555652

Pelvic osteolysis relationship to radiographs and polyethylene wear.

Won Yong Shon1, Siddhartha Gupta, Sandeep Biswal, Sang Hwan Han, Suk Joo Hong, Jun Gyu Moon.   

Abstract

The relationship of radiographic pelvic osteolysis to computed tomographic (CT) volume and polyethylene wear remains controversial. We evaluated the sensitivity and specificity of radiographs in detecting osteolysis considering CT scan as the true value, in 118 hips with cementless cups. Correlation between osteolysis volume in CT, area of osteolysis in radiograph, and linear wear of polyethylene was assessed. The sensitivity and specificity of anteroposterior radiographs for detection of osteolysis was 57.6% and 92.9%, respectively. Addition of oblique radiographs increased the sensitivity to 64.4% without changing the specificity. The sensitivity increased to 92.8% for lesion more than 1000 mm(3). There was good correlation between 2-dimensional (2D) osteolytic area in radiograph and 3-dimensional (3D) volume (r = 0.74) in CT scan and linear wear of polyethylene showed good correlation with 3D CT volume (r = 0.62) and 2D area in radiograph (r = 0.60). Thus radiographs are useful to screen clinically significant osteolysis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18555652     DOI: 10.1016/j.arth.2008.02.012

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  Relationship between the pelvic osteolytic volume on computed tomography and clinical outcome in patients with cementless acetabular components.

Authors:  Ho Hyun Yun; Won Yong Shon; Suk Joo Hong; Jung-Ro Yoon; Jae-Hyuk Yang
Journal:  Int Orthop       Date:  2010-10-07       Impact factor: 3.075

2.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

Review 3.  Acetabular defect classification in times of 3D imaging and patient-specific treatment protocols.

Authors:  K Horas; J Arnholdt; A F Steinert; M Hoberg; M Rudert; B M Holzapfel
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

4.  Monitoring and risk of progression of osteolysis after total hip arthroplasty.

Authors:  Michael D Ries; Thomas M Link
Journal:  J Bone Joint Surg Am       Date:  2012-11-21       Impact factor: 5.284

5.  Metal artefact suppression at 3 T MRI: comparison of MAVRIC-SL with conventional fast spin echo sequences in patients with Hip joint arthroplasty.

Authors:  Martin Kretzschmar; Lorenzo Nardo; Misung M Han; Ursula Heilmeier; Craig Sam; Gabby B Joseph; Kevin M Koch; Roland Krug; Thomas M Link
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

6.  Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.

Authors:  Robert H Hopper; Henry Ho; Supatra Sritulanondha; Ann C Williams; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

7.  High survivorship with a titanium-encased alumina ceramic bearing for total hip arthroplasty.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

8.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 9.  Nontraumatic Osteonecrosis of the Femoral Head: Where Do We Stand Today?: A 5-Year Update.

Authors:  Michael A Mont; Hytham S Salem; Nicolas S Piuzzi; Stuart B Goodman; Lynne C Jones
Journal:  J Bone Joint Surg Am       Date:  2020-06-17       Impact factor: 6.558

10.  Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study.

Authors:  Byung-Woo Min; Ki-Cheor Bae; Chul-Hyun Cho; Eun-Suck Son; Kyung-Jae Lee; Si-Wook Lee
Journal:  Indian J Orthop       Date:  2020-05-20       Impact factor: 1.251

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.