Literature DB >> 21852377

Feasibility of flat panel angiographic CT after intravenous contrast agent application in the postoperative evaluation of patients with clipped aneurysms.

M-N Psychogios1, D Wachter, A Mohr, P Schramm, A-M Frölich, K Jung, V Rohde, M Knauth.   

Abstract

BACKGROUND AND
PURPOSE: Important findings, such as aneurysm remnants or major arterial occlusion, can be detected on intra- or postoperative angiography after surgical clipping of intracranial aneurysms. The purpose of this study was to evaluate the feasibility of IV-ACT for the postoperative detection of residual aneurysms and parent vessel patency compared with IA-DSA, which was selected as the standard reference method.
MATERIALS AND METHODS: Twenty-two patients with 27 aneurysms treated by surgical clipping were examined by using both IA-DSA and IV-ACT. Both diagnostic procedures were performed on an FPD-equipped angiography system. Postprocessing of IV-ACT acquisitions was performed on a dedicated workstation producing multiplanar reformations and maximum intensity projections of the clip region and other intracranial arteries. Three interventional neuroradiologists independently evaluated both procedures.
RESULTS: A residual aneurysm was delineated in 10 cases with IA-DSA. Sufficient opacification of the intracranial vessels was assigned in 26 IV-ACT cases. Due to metal artifacts, IV-ACT images were tagged as "not diagnostic" on 8 occasions. In the other 19 aneurysms, a residual aneurysm was delineated in 6 cases-all 6 being true-positive compared with IA-DSA-and was excluded in the remaining 13 cases-all true-negative. Even small aneurysm remnants with a diameter of 1.5 mm were detected with IV-ACT.
CONCLUSIONS: Currently IV-ACT cannot be recommended as a routine tool for postoperative evaluation of clipped aneurysms due to metal artifacts in 30% of the examinations. These artifacts appear with multiple normal-sized or large clips. In patients with single or multiple small clips, IV-ACT can reliably show aneurysm remnants.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21852377      PMCID: PMC7965991          DOI: 10.3174/ajnr.A2611

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  41 in total

1.  Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

Authors:  M-N Psychogios; P Schramm; J-H Buhk; A Xyda; K Gröschel; K Jung; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

2.  Minimizing clip artifacts in multi CT angiography of clipped patients.

Authors:  I van der Schaaf; M van Leeuwen; A Vlassenbroek; B Velthuis
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

3.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

4.  Late angiographic follow-up review of surgically treated aneurysms.

Authors:  C A David; A G Vishteh; R F Spetzler; M Lemole; M T Lawton; S Partovi
Journal:  J Neurosurg       Date:  1999-09       Impact factor: 5.115

5.  Comparison of routine and selective use of intraoperative angiography during aneurysm surgery: a prospective assessment.

Authors:  Jeffrey D Klopfenstein; Robert F Spetzler; Louis J Kim; Iman Feiz-Erfan; Patrick P Han; Joseph M Zabramski; Randall W Porter; Felipe C Albuquerque; Cameron G McDougall; David J Fiorella
Journal:  J Neurosurg       Date:  2004-02       Impact factor: 5.115

6.  Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips.

Authors:  F Gönner; K O Lövblad; O Heid; L Remonda; R Guzman; A Barth; G Schroth
Journal:  Neuroradiology       Date:  2002-08-14       Impact factor: 2.804

Review 7.  [Postoperative arteriography in surgery for intracranial aneurysm. Prospective study in a consecutive series of 267 operated aneurysms].

Authors:  J C Acevedo; F Turjman; M Sindou
Journal:  Neurochirurgie       Date:  1997       Impact factor: 1.553

8.  Neuroradiologic applications with routine C-arm flat panel detector CT: evaluation of patient dose measurements.

Authors:  Y Kyriakou; G Richter; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-07       Impact factor: 3.825

9.  Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography.

Authors:  Max Wintermark; Antoine Uske; Marc Chalaron; Luca Regli; Philippe Maeder; Reto Meuli; Pierre Schnyder; Stefano Binaghi
Journal:  J Neurosurg       Date:  2003-04       Impact factor: 5.115

10.  Risks and benefits of diagnostic angiography after aneurysm surgery: a retrospective analysis of 597 studies.

Authors:  P D Le Roux; J P Elliott; J M Eskridge; W Cohen; H R Winn
Journal:  Neurosurgery       Date:  1998-06       Impact factor: 4.654

View more
  6 in total

1.  Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms.

Authors:  Caterina Budai; Luigi Cirillo; Francesco Patruno; Massimo Dall'olio; Ciro Princiotta; Marco Leonardi
Journal:  Neuroradiol J       Date:  2014-04-18

2.  Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results.

Authors:  Marios-Nikos Psychogios; Bernhard Scholz; Christopher Rohkohl; Yiannis Kyriakou; Alexander Mohr; Peter Schramm; Dorothee Wachter; Katrin Wasser; Michael Knauth
Journal:  Neuroradiology       Date:  2013-04-16       Impact factor: 2.804

3.  Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

Authors:  Sabine Ott; Philipp Gölitz; Edyta Adamek; Kevin Royalty; Arnd Doerfler; Tobias Struffert
Journal:  Interv Neuroradiol       Date:  2015-06-25       Impact factor: 1.610

4.  Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

Authors:  T Struffert; S Lang; E Adamek; T Engelhorn; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-05-28       Impact factor: 3.649

5.  The application of the unruptured intracranial aneurysm treatment score: a retrospective, single-center study.

Authors:  Silvia Hernández-Durán; Dorothee Mielke; Veit Rohde; Vesna Malinova
Journal:  Neurosurg Rev       Date:  2018-02-01       Impact factor: 3.042

6.  Intravenous flat-detector computed tomography angiography for symptomatic cerebral vasospasm following aneurysmal subarachnoid hemorrhage.

Authors:  Jin Pyeong Jeon; Seung Hun Sheen; Yong-Jun Cho
Journal:  ScientificWorldJournal       Date:  2014-10-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.