Literature DB >> 26111985

Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

Sabine Ott1, Philipp Gölitz2, Edyta Adamek2, Kevin Royalty3, Arnd Doerfler2, Tobias Struffert2.   

Abstract

We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting.
© The Author(s) 2015.

Entities:  

Keywords:  Endovascular treatment; experimental aneurysms; flat-detector computed tomography; follow-up examination

Mesh:

Substances:

Year:  2015        PMID: 26111985      PMCID: PMC4757313          DOI: 10.1177/1591019915590364

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  29 in total

1.  Intracranial aneurysm stenting: follow-up with MR angiography.

Authors:  Karl-Olof Lövblad; Hasan Yilmaz; Amine Chouiter; Diego San Millan Ruiz; German Abdo; Philippe Bijlenga; Nicolas de Tribolet; Daniel A Ruefenacht
Journal:  J Magn Reson Imaging       Date:  2006-08       Impact factor: 4.813

2.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

3.  A novel forward projection-based metal artifact reduction method for flat-detector computed tomography.

Authors:  Daniel Prell; Yiannis Kyriakou; Marcel Beister; Willi A Kalender
Journal:  Phys Med Biol       Date:  2009-10-14       Impact factor: 3.609

4.  Coil-treated aneurysms: decision making regarding additional treatment based on findings of MR angiography and intraarterial DSA.

Authors:  Joanna D Schaafsma; Birgitta K Velthuis; René van den Berg; Patrick A Brouwer; Charles B L M Majoie; Frederik Barkhof; Omid Eshghi; Gerard A P de Kort; Rob T H Lo; Marieke E S Sprengers; Willem-Jan van Rooij; Joseph C Bot; Gabriël J E Rinkel
Journal:  Radiology       Date:  2012-09-25       Impact factor: 11.105

5.  Flat-detector computed tomography with intravenous contrast material application in experimental aneurysms: comparison with multislice CT and conventional angiography.

Authors:  Tobias Struffert; Marc Doelken; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Sabine Ott; Arnd Doerfler
Journal:  Acta Radiol       Date:  2010-05       Impact factor: 1.990

6.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

7.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

8.  Onyx in an experimental aneurysm model: histological and angiographic results.

Authors:  Tobias Struffert; Christian Roth; Bernd Romeike; Iris O Grunwald; Wolfgang Reith
Journal:  J Neurosurg       Date:  2008-07       Impact factor: 5.115

9.  Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT.

Authors:  M Doelken; T Struffert; G Richter; T Engelhorn; C Nimsky; O Ganslandt; T Hammen; A Doerfler
Journal:  Neuroradiology       Date:  2008-03-11       Impact factor: 2.804

10.  Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling.

Authors:  I M J van der Bom; S Y Hou; A S Puri; G Spilberg; D Ruijters; P van de Haar; B Carelsen; S Vedantham; M J Gounis; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-30       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.