Literature DB >> 21960501

Applicability of tableside flat panel detector CT parenchymal cerebral blood volume measurement in neurovascular interventions: preliminary clinical experience.

P Mordasini1, M El-Koussy, C Brekenfeld, G Schroth, U Fischer, J Beck, J Gralla.   

Abstract

BACKGROUND AND
PURPOSE: CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical experience with this new imaging tool in different neurovascular interventions.
MATERIALS AND METHODS: FPD-CBV measurement was performed on a biplane FPD angiographic system. Eighteen patients (11 women, 7 men) were examined (age range, 18-86 years; median, 58.7 years). In the 10 patients with stroke, the extent of intracranial hypoperfusion was evaluated. The remaining 8 patients had an intracranial hemorrhage; periprocedural CBV was evaluated during the course of interventional treatment.
RESULTS: In the 18 cases studied, 23 CBV measurements were performed. Twenty acquisitions were of sufficient diagnostic quality. The remaining 3 acquisitions failed technically, 1 due to motion artifacts and 2 due to injection technique and/or hardware failure.
CONCLUSIONS: FPD-CBV measurement in the angiography suite provides a feasible and helpful tool for peri-interventional neuroimaging. It extends the intraprocedural imaging modalities to the level of tissue perfusion. However, the technique has technical limitations and shows room for improvement in the future.

Entities:  

Mesh:

Year:  2011        PMID: 21960501      PMCID: PMC7966151          DOI: 10.3174/ajnr.A2715

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  14 in total

1.  Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

Authors:  M-N Psychogios; P Schramm; J-H Buhk; A Xyda; K Gröschel; K Jung; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

2.  CT angiographic source images: flow- or volume-weighted?

Authors:  M Sharma; A J Fox; S Symons; A Jairath; R I Aviv
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-04       Impact factor: 3.825

3.  C-arm CT measurement of cerebral blood volume: an experimental study in canines.

Authors:  A S Ahmed; M Zellerhoff; C M Strother; K A Pulfer; T Redel; Y Deuerling-Zheng; K Royalty; D Consigny; D B Niemann
Journal:  AJNR Am J Neuroradiol       Date:  2009-03-19       Impact factor: 3.825

4.  Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Authors:  Tobias Struffert; Gregor Richter; Tobias Engelhorn; Marc Doelken; Philipp Goelitz; Willi A Kalender; Oliver Ganslandt; Arnd Doerfler
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

5.  Flat panel detector angiographic CT in the management of aneurysmal rupture during coil embolization.

Authors:  T Engelhorn; T Struffert; G Richter; M Doelken; O Ganslandt; W Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-22       Impact factor: 3.825

6.  Clinical evaluation of flat-panel detector compared with multislice computed tomography in 65 patients with acute intracranial hemorrhage: initial results. Clinical article.

Authors:  Tobias Struffert; Ilker Y Eyupoglu; Hagen B Huttner; Tobias Engelhorn; Marc Doelken; Marc Saake; Oliver Ganslandt; Arnd Doerfler
Journal:  J Neurosurg       Date:  2010-10       Impact factor: 5.115

7.  C-arm CT measurement of cerebral blood volume in ischemic stroke: an experimental study in canines.

Authors:  T Bley; C M Strother; K Pulfer; K Royalty; M Zellerhoff; Y Deuerling-Zheng; F Bender; D Consigny; R Yasuda; D Niemann
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-06       Impact factor: 3.825

8.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

9.  AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data.

Authors:  Philip M White; John N Gilmour; Nicholas W Weir; Brian Innes; Robin J Sellar
Journal:  Neuroradiology       Date:  2007-12-21       Impact factor: 2.804

10.  Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT.

Authors:  M Doelken; T Struffert; G Richter; T Engelhorn; C Nimsky; O Ganslandt; T Hammen; A Doerfler
Journal:  Neuroradiology       Date:  2008-03-11       Impact factor: 2.804

View more
  16 in total

1.  Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results.

Authors:  Marios-Nikos Psychogios; Bernhard Scholz; Christopher Rohkohl; Yiannis Kyriakou; Alexander Mohr; Peter Schramm; Dorothee Wachter; Katrin Wasser; Michael Knauth
Journal:  Neuroradiology       Date:  2013-04-16       Impact factor: 2.804

2.  Implication of cerebral circulation time in intracranial stenosis measured by digital subtraction angiography on cerebral blood flow estimation measured by arterial spin labeling.

Authors:  Kay Jann; Martinus Hauf; Frauke Kellner Weldon; Marwan El Koussy; Claus Kiefer; Andrea Federspiel; Gerhard Schroth
Journal:  Diagn Interv Radiol       Date:  2016 Sep-Oct       Impact factor: 2.630

3.  Use of time attenuation curves to determine steady-state characteristics before C-arm CT measurement of cerebral blood volume.

Authors:  Jildaz Caroff; Pakrit Jittapiromsak; Daniel Ruijters; Nidhal Benachour; Cristian Mihalea; Aymeric Rouchaud; Hiroaki Neki; Léon Ikka; Jacques Moret; Laurent Spelle
Journal:  Neuroradiology       Date:  2014-01-23       Impact factor: 2.804

4.  Predictive Value of Pooled Cerebral Blood Volume Mapping for Final Infarct Volume in Patients with Major Artery Occlusions. A Retrospective Analysis.

Authors:  Lauma Ava; Joachim Berkefeld; Arne Lauer; Alexander Seiler; Waltraud Pfeilschifter; Monika Müller-Eschner; Se-Jong You; Stefan Weidauer; Ulrich Pilatus; Marlies Wagner
Journal:  Clin Neuroradiol       Date:  2017-03-13       Impact factor: 3.649

5.  C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

Authors:  Mudassar Kamran; James V Byrne
Journal:  Neuroradiology       Date:  2015-05-29       Impact factor: 2.804

6.  Feasibility of Flat Panel Detector CT in Perfusion Assessment of Brain Arteriovenous Malformations: Initial Clinical Experience.

Authors:  M Garcia; T W Okell; M Gloor; M A Chappell; P Jezzard; O Bieri; J V Byrne
Journal:  AJNR Am J Neuroradiol       Date:  2017-02-16       Impact factor: 3.825

7.  Use of cone-beam computed tomography angiography in planning for gamma knife radiosurgery for arteriovenous malformations: a case series and early report.

Authors:  Mina G Safain; Jason P Rahal; Ami Raval; Mark J Rivard; John E Mignano; Julian K Wu; Adel M Malek
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

8.  Evaluation of Cerebral Hyperperfusion After Carotid Artery Stenting Using C‑Arm CT Measurements of Cerebral Blood Volume.

Authors:  Michio Fujimoto; Hiroshi Itokawa; Masao Moriya; Noriyoshi Okamoto; Jinichi Sasanuma
Journal:  Clin Neuroradiol       Date:  2016-12-11       Impact factor: 3.649

9.  C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.

Authors:  K Royalty; M Manhart; K Pulfer; Y Deuerling-Zheng; C Strother; A Fieselmann; D Consigny
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-23       Impact factor: 3.825

10.  Whole brain C-arm computed tomography parenchymal blood volume measurements.

Authors:  Mudassar Kamran; James V Byrne
Journal:  Interv Neuroradiol       Date:  2016-01-14       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.