The use of a cemented dual mobility socket to treat recurrent dislocation.

Moussa Hamadouche1, David J Biau, Denis Huten, Thierry Musset, François Gaucher.   

Abstract

BACKGROUND: The treatment of recurrent dislocation after total hip arthroplasty remains challenging. Dual mobility sockets have been associated with a low rate of dislocation but it is not known whether they are useful for treating recurrent dislocation. QUESTIONS/PURPOSES: We therefore asked whether a cemented dual mobility socket would (1) restore hip stability following recurrent dislocation; (2) provide a pain-free and mobile hip; and (3) show durable radiographic fixation.
METHODS: We retrospectively reviewed 51 patients treated with a cemented dual mobility socket for recurrent dislocation after total hip arthroplasty between August 2002 and June 2005. The mean age at the time of the index procedure of was 71.3 years. Of the 51 patients, 47 have had complete clinical and radiographic evaluation data at a mean followup of 51.4 months (range, 25-76.3 months).
RESULTS: The cemented dual mobility socket restored complete stability of the hip in 45 of the 47 patients (96%). The mean Merle d'Aubigné hip score was 16 ± 2 at the latest followup. Radiographic analysis revealed no or radiolucent lines less than 1 mm thick located in a single acetabular zone in 43 of 47 hips (91.5%). The cumulative survival rate of the acetabular component at 72 months using revision for dislocation and/or mechanical failure as the end point was 96% ± 4% (95% confidence interval, 90%-100%).
CONCLUSIONS: A cemented dual mobility socket was able to restore hip stability in 96% of recurrent dislocating hips. However, longer-term followup is needed to ensure that dislocation and loosening rates will not increase.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20532718      PMCID: PMC2974879          DOI: 10.1007/s11999-010-1404-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  48 in total

1.  [Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants].

Authors:  P Adam; F Farizon; M-H Fessy
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-11

2.  Unconstrained tripolar hip implants: effect on hip stability.

Authors:  Olivier Guyen; Qing Shan Chen; Jacques Bejui-Hugues; Daniel J Berry; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2007-02       Impact factor: 4.176

3.  Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

Authors:  Olivier Guyen; David G Lewallen; Miguel E Cabanela
Journal:  J Bone Joint Surg Am       Date:  2008-07       Impact factor: 5.284

4.  Failure of a constrained acetabular prosthesis of a total hip arthroplasty. A report of four cases.

Authors:  B P Kaper; P M Bernini
Journal:  J Bone Joint Surg Am       Date:  1998-04       Impact factor: 5.284

5.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.

Authors:  R L Barrack; R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1992-05

6.  Further follow-up on socket fixation using a metal-backed acetabular component for total hip replacement. A minimum ten-year follow-up study.

Authors:  W H Harris; B L Penenberg
Journal:  J Bone Joint Surg Am       Date:  1987-10       Impact factor: 5.284

7.  Biomechanics of bipolar hip endoprostheses.

Authors:  S W Krein; E Y Chao
Journal:  J Orthop Res       Date:  1984       Impact factor: 3.494

8.  The functional cost of dislocation following total hip arthroplasty.

Authors:  R W Chandler; L D Dorr; J Perry
Journal:  Clin Orthop Relat Res       Date:  1982-08       Impact factor: 4.176

9.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

10.  Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component. A concise follow-up of a previous report.

Authors:  Devon D Goetz; Barron R B Bremner; John J Callaghan; William N Capello; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2004-11       Impact factor: 5.284

View more
  39 in total

1.  Is a cementless dual mobility socket in primary THA a reasonable option?

Authors:  Moussa Hamadouche; Hervé Arnould; Bertrand Bouxin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

Review 2.  Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.

Authors:  Christian Fabry; Jean Langlois; Moussa Hamadouche; Rainer Bader
Journal:  Int Orthop       Date:  2015-10-01       Impact factor: 3.075

3.  Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital.

Authors:  Sebastian S Mukka; Sarwar S Mahmood; Göran O Sjödén; Arkan S Sayed-Noor
Journal:  Orthop Rev (Pavia)       Date:  2013-06-11

4.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

5.  All dual mobility cups are not the same.

Authors:  Thierry Aslanian
Journal:  Int Orthop       Date:  2017-01-18       Impact factor: 3.075

Review 6.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

Review 7.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 8.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

9.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

Review 10.  Risk of revision and dislocation in single, dual mobility and large femoral head total hip arthroplasty: systematic review and network meta-analysis.

Authors:  Kwanchai Pituckanotai; Alisara Arirachakaran; Harit Tuchinda; Chinundorn Putananon; Nitiphol Nualsalee; Kittipong Setrkraising; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.