Literature DB >> 23888200

Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital.

Sebastian S Mukka1, Sarwar S Mahmood, Göran O Sjödén, Arkan S Sayed-Noor.   

Abstract

Dislocation remains a major concern after hip arthroplasty. We asked whether dual mobility cups (DMC) would improve early hip stability in patients with high risk of dislocation. We followed 34 patients (21 females, 13 males) treated between 2009 and 2012 with cemented DMC for hip revisions caused recurrent hip prosthetic dislocation or as a primary procedure in patients with high risk of instability. Functional outcome and quality of life were evaluated using Harris Hip Score and EQ-5D respectively. We found that the cemented DMC gave stability in 94%. Seven patients (20%) were re-operated due to infection. One patient sustained a periprosthetic fracture. At follow-up (6 to 36 months, mean 18), the mean Harris hip score was 67 (standard deviation: 14) and mean EQ-5D was 0.76 (standard deviation: 0.12). We concluded that treating patients with high risk of dislocation with DMC can give good stability. However, complications such as postoperative infection can be frequent and should be managed carefully.

Entities:  

Keywords:  complications; dislocation; dual mobility cup; hip arthroplasty; outcome; stability

Year:  2013        PMID: 23888200      PMCID: PMC3718234          DOI: 10.4081/or.2013.e10

Source DB:  PubMed          Journal:  Orthop Rev (Pavia)        ISSN: 2035-8164


  24 in total

1.  Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up.

Authors:  F Leiber-Wackenheim; B Brunschweiler; M Ehlinger; A Gabrion; P Mertl
Journal:  Orthop Traumatol Surg Res       Date:  2011-01-26       Impact factor: 2.256

Review 2.  The dislocating hip: what to do, what to do.

Authors:  Robert B Bourne; Ramin Mehin
Journal:  J Arthroplasty       Date:  2004-06       Impact factor: 4.757

3.  Prevention and treatment of dislocation after total hip replacement using large diameter balls.

Authors:  Harlan C Amstutz; Michel J Le Duff; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

4.  [Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants].

Authors:  P Adam; F Farizon; M-H Fessy
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-11

5.  Use of a dual mobility socket to manage total hip arthroplasty instability.

Authors:  Olivier Guyen; Vincent Pibarot; Gualter Vaz; Christophe Chevillotte; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2008-09-09       Impact factor: 4.176

6.  Revision for recurrent instability: what are the predictors of failure?

Authors:  Aaron H Carter; Eoin C Sheehan; S M Javad Mortazavi; James J Purtill; Peter F Sharkey; Javad Parvizi
Journal:  J Arthroplasty       Date:  2011-05-08       Impact factor: 4.757

7.  Femoral head diameter affects the revision rate in total hip arthroplasty: an analysis of 1,720 hip replacements with 9-21 years of follow-up.

Authors:  Sarunas Tarasevicius; Uldis Kesteris; Otto Robertsson; Hans Wingstrand
Journal:  Acta Orthop       Date:  2006-10       Impact factor: 3.717

8.  Internal fixation versus total hip arthroplasty in the treatment of displaced femoral neck fractures: a prospective randomized study of 100 hips.

Authors:  T Johansson; S A Jacobsson; I Ivarsson; A Knutsson; O Wahlström
Journal:  Acta Orthop Scand       Date:  2000-12

9.  The use of a tripolar articulation in revision total hip arthroplasty: a minimum of 24 months' follow-up.

Authors:  Brett R Levine; Craig J Della Valle; Carl A Deirmengian; Kristoffer M Breien; Steven H Weeden; Scott M Sporer; Wayne G Paprosky
Journal:  J Arthroplasty       Date:  2008-03-04       Impact factor: 4.757

Review 10.  Orthopaedic procedure volume and patient outcomes: a systematic literature review.

Authors:  Nina Shervin; Harry E Rubash; Jeffrey N Katz
Journal:  Clin Orthop Relat Res       Date:  2007-04       Impact factor: 4.176

View more
  3 in total

Review 1.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

2.  No dislocations after primary hip arthroplasty with the dual mobility cup in displaced femoral neck fracture in patients with dementia. A one-year follow-up in 20 patients.

Authors:  Anders Elneff Graversen; Stig Storgaard Jakobsen; Pia Kjær Kristensen; Theis Muncholm Thillemann
Journal:  SICOT J       Date:  2017-02-10

3.  Dual mobility cups in primary total hip arthroplasties: trend over time in use, patient characteristics, and mid-term revision in 3,038 cases in the Dutch Arthroplasty Register (2007-2016).

Authors:  Esther M Bloemheuvel; Liza N van Steenbergen; Bart A Swierstra
Journal:  Acta Orthop       Date:  2018-11-19       Impact factor: 3.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.