Literature DB >> 28091768

Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Luigi Zagra1, Eleonora Caboni2.   

Abstract

Dual mobility cups are getting increasing interest for the prevention, but also in the treatment of THA instability. Nevertheless when a dislocation occurs the main issue remains the knowledge and the correction of the causes of dislocation, including reorientation of the components and soft tissues treatment. There are several options of alternative implants to DMCs including upsizing of the head, and constrained liners. The Authors present how to evaluate patients with THA instability, the advantages and the disadvantages of each procedure and their experience in the treatment of cases without DMCs during a five years' time period.

Entities:  

Keywords:  Constrained liner; Dislocation; Dual mobility cup; Hip; Revision; THR instability; Total hip arthroplasty; ᅟTHA

Mesh:

Year:  2017        PMID: 28091768     DOI: 10.1007/s00264-016-3383-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  60 in total

1.  Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up.

Authors:  F Leiber-Wackenheim; B Brunschweiler; M Ehlinger; A Gabrion; P Mertl
Journal:  Orthop Traumatol Surg Res       Date:  2011-01-26       Impact factor: 2.256

2.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

Review 3.  Instability after total hip arthroplasty.

Authors:  B F Morrey
Journal:  Orthop Clin North Am       Date:  1992-04       Impact factor: 2.472

4.  Constrained liners in revision total hip arthroplasty: an overuse syndrome: in the affirmative.

Authors:  Kevin B Fricka; Amanda Marshall; Wayne G Paprosky
Journal:  J Arthroplasty       Date:  2006-06       Impact factor: 4.757

5.  A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions.

Authors:  Roberto Civinini; Christian Carulli; Fabrizio Matassi; Lorenzo Nistri; Massimo Innocenti
Journal:  Clin Orthop Relat Res       Date:  2012-06-15       Impact factor: 4.176

6.  Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management.

Authors:  R S Turner
Journal:  Clin Orthop Relat Res       Date:  1994-04       Impact factor: 4.176

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  Hip abductor defect repair by means of a vastus lateralis muscle shift.

Authors:  Sandro Kohl; Dimitrios S Evangelopoulos; Klaus A Siebenrock; Martin Beck
Journal:  J Arthroplasty       Date:  2011-09-09       Impact factor: 4.757

9.  Dislocation after total hip arthroplasty with 28 and 32-mm femoral head.

Authors:  Einar Amlie; Øystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-05-27

Review 10.  The unstable total hip arthroplasty.

Authors:  Gösta Ullmark
Journal:  EFORT Open Rev       Date:  2017-03-13
View more
  7 in total

1.  Dual-mobility cup: a new French revolution.

Authors:  Jacques Henri Caton; André Ferreira
Journal:  Int Orthop       Date:  2017-02-14       Impact factor: 3.075

2.  A comparative study about the incidence of dislocation and peri-prosthetic fracture between dual mobility versus standard cups after primary total hip arthroplasty.

Authors:  Elliot Sappey-Marinier; Anthony Viste; Yoann Blangero; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2019-01-05       Impact factor: 3.075

3.  Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

Authors:  Justinas Stucinskas; Tomas Kalvaitis; Alfredas Smailys; Otto Robertsson; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2017-12-02       Impact factor: 3.075

4.  The Patient With Chronic Total Hip Arthroplasty Dislocations: A Case Series of Five Patients Who Underwent Revision THA Using Polypropylene Mesh for Capsular Reconstruction.

Authors:  Joseph M Nessler; Joseph P Nessler
Journal:  Arthroplast Today       Date:  2020-08-22

5.  Novel Constrained Dual Mobility Hip Prosthesis to Combat Instability in Revision Total Hip Arthroplasty whilst Preserving Normal Function.

Authors:  Michael Jiang; Anton Lambers; Rodney Richardson
Journal:  Case Rep Orthop       Date:  2020-07-07

6.  Constrained acetabular liners are a viable option in second-stage re-implantation for chronic infected total hip arthroplasty with abductor or greater trochanter deficiency and large acetabular bone defects.

Authors:  Qiang Xiao; Tingxian Ling; Kai Zhou; Mingcheng Yuan; Bing Xu; Zongke Zhou
Journal:  BMC Musculoskelet Disord       Date:  2022-10-14       Impact factor: 2.562

7.  What Is the Dislocation and Revision Rate of Dual-mobility Cups Used in Complex Revision THAs?

Authors:  Niklas Unter Ecker; Hakan Kocaoğlu; Akos Zahar; Carl Haasper; Thorsten Gehrke; Mustafa Citak
Journal:  Clin Orthop Relat Res       Date:  2021-02-01       Impact factor: 4.755

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.