Literature DB >> 6527161

Biomechanics of bipolar hip endoprostheses.

S W Krein, E Y Chao.   

Abstract

The bipolar endoprosthesis was designed to alleviate problems encountered with conventional hip endoprostheses. Recent designs have advocated the use of offset centers of rotation between the inner and outer joint-bearing surfaces to generate a valgus-producing moment on loading (antivarus head dynamics). This study was undertaken to justify this biomechanical feature by performing (a) cyclic loading of the bipolar head in the varus position, (b) analysis of motion between the inner and outer bearing surfaces, and (c) evaluation of antivarus head dynamic function. Four endoprosthetic designs were studied: the Bateman UPF, Osteonics UHR, Giliberty II, and Bi-Centric. Significant plastic deformation occurred in the UPF and UHR prostheses when loaded in an extreme varus position. Theoretically, motion is most likely to occur at the inner bearing if the frictional coefficients are equal at both surfaces. The UHR prosthesis with eccentric offset of bearing centers can provide the antivarus effect in laboratory conditions. Whether the antivarus effect and/or the dominant inner bearing motion will occur in vivo awaits careful clinical study.

Entities:  

Mesh:

Year:  1984        PMID: 6527161     DOI: 10.1002/jor.1100020408

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  The use of a cemented dual mobility socket to treat recurrent dislocation.

Authors:  Moussa Hamadouche; David J Biau; Denis Huten; Thierry Musset; François Gaucher
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 2.  Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.

Authors:  Christian Fabry; Jean Langlois; Moussa Hamadouche; Rainer Bader
Journal:  Int Orthop       Date:  2015-10-01       Impact factor: 3.075

3.  Adventure sports and sexual freedom hip replacement: the tripolar hip.

Authors:  James W Pritchett
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-06-28

4.  What Is the Frequency of Early Dissociation of Bipolar Cups and What Factors Are Associated With Dissociation?

Authors:  Young-Kyun Lee; Chan Ho Park; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2018-08       Impact factor: 4.176

5.  The Exeter bipolar prosthesis in the active elderly patient: the results at 7 years.

Authors:  M F Pearse; S Bande; K J O'Dwyer; R S Ling
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

6.  Five cases of early dissociation between the bipolar hip endoprosthesis cup components; either spontaneously or during reduction maneuvers.

Authors:  Vedat Uruç; Raif Özden; İbrahim Gökhan Duman; Aydıner Kalacı
Journal:  Acta Orthop Traumatol Turc       Date:  2017-02-21       Impact factor: 1.511

7.  The BHU bicentric bipolar prosthesis in fracture neck femur in active elderly.

Authors:  Anil K Rai; Rakesh Agarwal; Saurabh Singh; Ratnav Ratan
Journal:  J Trauma Manag Outcomes       Date:  2008-09-25

8.  Hip stress distribution - Predictor of dislocation in hip arthroplasties. A retrospective study of 149 arthroplasties.

Authors:  Matevž Tomaževič; Tina Kaiba; Urban Kurent; Rihard Trebše; Matej Cimerman; Veronika Kralj-Iglič
Journal:  PLoS One       Date:  2019-11-20       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.