Literature DB >> 28097416

[Use of dual mobility cups for revision hip arthroplasty].

E Röhner1, G Matziolis2.   

Abstract

The dual mobility cup (DMC) is an increasingly important tool not only in primary but also in revision total hip arthroplasty to prevent dislocation and eventually reduce postoperative complication rates. Various studies have shown survival rates with DMCs of up to 100% with an average dislocation rate of less than 1.5% after primary hip arthroplasty and a follow-up of 10 years. In revision surgery, survival rates of up to 99% were reported with dislocation rates between 0 and 10% after an average of 5 years after implantation. This article is intended to provide an overview of the principle and function of DMCs. Furthermore, indications as well as complications are presented.

Entities:  

Keywords:  Complication, postoperative; Hip displacement; Revision surgery; Total hip replacement; Trochanter

Mesh:

Year:  2017        PMID: 28097416     DOI: 10.1007/s00132-016-3383-1

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  49 in total

1.  Experimental and computational simulation of total hip arthroplasty dislocation.

Authors:  C F Scifert; P C Noble; T D Brown; R L Bartz; N Kadakia; N Sugano; R C Johnston; D R Pedersen; J J Callaghan
Journal:  Orthop Clin North Am       Date:  2001-10       Impact factor: 2.472

2.  Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up.

Authors:  F Leiber-Wackenheim; B Brunschweiler; M Ehlinger; A Gabrion; P Mertl
Journal:  Orthop Traumatol Surg Res       Date:  2011-01-26       Impact factor: 2.256

3.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

4.  Unconstrained tripolar hip implants: effect on hip stability.

Authors:  Olivier Guyen; Qing Shan Chen; Jacques Bejui-Hugues; Daniel J Berry; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2007-02       Impact factor: 4.176

Review 5.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

6.  Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up : A prospective and comparative series.

Authors:  Jean-Marc Puch; Guy Derhi; Loys Descamps; Régis Verdier; Jacques H Caton
Journal:  Int Orthop       Date:  2016-11-08       Impact factor: 3.075

7.  A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions.

Authors:  Roberto Civinini; Christian Carulli; Fabrizio Matassi; Lorenzo Nistri; Massimo Innocenti
Journal:  Clin Orthop Relat Res       Date:  2012-06-15       Impact factor: 4.176

8.  Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty.

Authors:  Daniel J Berry; Marius von Knoch; Cathy D Schleck; William S Harmsen
Journal:  J Bone Joint Surg Am       Date:  2005-11       Impact factor: 5.284

9.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

10.  Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture.

Authors:  Sarunas Tarasevicius; Mantas Busevicius; Otto Robertsson; Hans Wingstrand
Journal:  BMC Musculoskelet Disord       Date:  2010-08-06       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.