Literature DB >> 19714387

Quantification of pelvic tilt in total hip arthroplasty.

Jinjun Zhu1, Zhinian Wan, Lawrence D Dorr.   

Abstract

UNLABELLED: In THA, anterior or posterior tilt of the pelvis changes the position of the acetabular component on the coronal plane of the body as compared with its anatomic position in the pelvic bone. To understand the occurrence and clinical importance for patients with pelvic tilt on an operating room table in the lateral decubitus position, we studied 436 patients (477 hips) undergoing primary THA using an imageless computer navigation system that measured tilt. We determined the distribution and magnitude of pelvic tilt, especially tilt of 10 degrees or greater. The distribution of tilt had a range of 25 degrees posterior to 20 degrees anterior. Twenty-nine of 477 (6.1%) hips had zero tilt; 251 (52.6%) had tilt of 1 degrees to 5 degrees; 120 (25.2%) had tilt of 6 degrees to 9 degrees; and 77 (16.1%) had tilt of 10 degrees or greater. The conversion factor for acetabular anteversion has been determined by a mathematical formula by Lembeck et al. and was confirmed by us in practice. Measurement of pelvic tilt during the performance of THA will improve the accuracy of cup position, especially allowing anteversion to be measured on the coronal plane. LEVEL OF EVIDENCE: Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2009        PMID: 19714387      PMCID: PMC2806995          DOI: 10.1007/s11999-009-1064-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  20 in total

1.  Pelvic inclination and spatial orientation of the acetabulum. A radiographic, computed tomographic and clinical investigation.

Authors:  S Anda; S Svenningsen; T Grontvedt; P Benum
Journal:  Acta Radiol       Date:  1990-07       Impact factor: 1.990

2.  Pelvic tilt makes acetabular cup navigation inaccurate.

Authors:  Burkhard Lembeck; Otto Mueller; Patrik Reize; Nikolaus Wuelker
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

3.  The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements.

Authors:  Fumihiro Yoshimine
Journal:  J Biomech       Date:  2006       Impact factor: 2.712

4.  Development of imageless computer navigation for acetabular component position in total hip replacement.

Authors:  Lawrence D Dorr; Yuji Hishiki; Zhinian Wan; Deanne Newton; Andrew Yun
Journal:  Iowa Orthop J       Date:  2005

5.  A validation model for measurement of acetabular component position.

Authors:  Aamer Malik; Zhinian Wan; Branislav Jaramaz; Gary Bowman; Lawrence D Dorr
Journal:  J Arthroplasty       Date:  2009-06-24       Impact factor: 4.757

6.  Anatomic referencing of cup orientation in total hip arthroplasty.

Authors:  Moritz Tannast; Ulrich Langlotz; Klaus-Arno Siebenrock; Matthias Wiese; Kai Bernsmann; Frank Langlotz
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

7.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Measurements of pelvic flexion angle using three-dimensional computed tomography.

Authors:  Shunsaku Nishihara; Nobuhiko Sugano; Takashi Nishii; Kenji Ohzono; Hideki Yoshikawa
Journal:  Clin Orthop Relat Res       Date:  2003-06       Impact factor: 4.176

10.  The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment.

Authors:  A M DiGioia; B Jaramaz; M Blackwell; D A Simon; F Morgan; J E Moody; C Nikou; B D Colgan; C A Aston; R S Labarca; E Kischell; T Kanade
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

View more
  39 in total

1.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

2.  Robotic assisted total hip arthroplasty using the MAKO platform.

Authors:  Rupesh Tarwala; Lawrence D Dorr
Journal:  Curr Rev Musculoskelet Med       Date:  2011-09

3.  Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.

Authors:  Weifeng Ji; Nathaniel Stewart
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

4.  Letter to the Editor: Editor's Spotlight/Take 5: No Benefit after THA Performed with Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Authors:  Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2016-11-17       Impact factor: 4.176

5.  Pelvic flexion measurement from lateral projection radiographs is clinically reliable.

Authors:  Norio Imai; Tomoyuki Ito; Ken Suda; Dai Miyasaka; Naoto Endo
Journal:  Clin Orthop Relat Res       Date:  2013-01-03       Impact factor: 4.176

6.  Difference in the acetabular cup orientation in standing and supine radiographs.

Authors:  Munir Khan; Tom Beckingsale; Martin Marsh; Jim Holland
Journal:  J Orthop       Date:  2016-04-05

Review 7.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

8.  Repeated posterior dislocation of total hip arthroplasty after spinal corrective long fusion with pelvic fixation.

Authors:  Hiroki Furuhashi; Daisuke Togawa; Hiroshi Koyama; Hironobu Hoshino; Tatsuya Yasuda; Yukihiro Matsuyama
Journal:  Eur Spine J       Date:  2016-11-17       Impact factor: 3.134

9.  An Alternative Intraoperative Radiographic Method for Optimizing Cup Inclination during Total Hip Arthroplasty.

Authors:  Gang-Yong Huang; Guang-Lei Zhao; Jun Xia; Yi-Bing Wei; Si-Qun Wang; Jian-Guo Wu
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

10.  Does fluoroscopy with anterior hip arthroplasty decrease acetabular cup variability compared with a nonguided posterior approach?

Authors:  Parthiv A Rathod; Sean Bhalla; Ajit J Deshmukh; Jose A Rodriguez
Journal:  Clin Orthop Relat Res       Date:  2014-02-19       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.