Literature DB >> 19553075

A validation model for measurement of acetabular component position.

Aamer Malik1, Zhinian Wan, Branislav Jaramaz, Gary Bowman, Lawrence D Dorr.   

Abstract

There is no agreement on a standard approach to evaluating acetabular cup orientation, ideal target orientation, or a standardized measurement method for cup orientation in total hip arthroplasty. The purpose of this study was to investigate a simple method for validating measurements of acetabular orientation obtained using computer navigation and computed tomography scans. This study validated the imageless navigation system to be accurate with a precision of 1 degrees and a bias of 0.02 degrees for inclination and a precision of 1.3 degrees and a bias of 0 degrees for anteversion measurements. From this study, we propose that acetabular cup alignment is accurately assessed using computer navigation. We suggest acetabular orientation be reported in the radiographic plane (coronal plane), which incorporates pelvic tilt and therefore is more functional definition of cup position. Copyright (c) 2010. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19553075     DOI: 10.1016/j.arth.2009.04.021

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  20 in total

1.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

2.  Quantification of pelvic tilt in total hip arthroplasty.

Authors:  Jinjun Zhu; Zhinian Wan; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2009-08-28       Impact factor: 4.176

3.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

4.  Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Authors:  Ming Lu; Yi-Xin Zhou; Hui Du; Ji Zhang; Jian Liu
Journal:  Clin Orthop Relat Res       Date:  2013-05-04       Impact factor: 4.176

5.  Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography.

Authors:  Vahdettin Bayraktar; Markus Weber; Frederik von Kunow; Florian Zeman; Benjamin Craiovan; Tobias Renkawitz; Joachim Grifka; Michael Woerner
Journal:  Int Orthop       Date:  2016-06-08       Impact factor: 3.075

Review 6.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

7.  Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Int Orthop       Date:  2018-02-17       Impact factor: 3.075

8.  Assessment of pelvic tilt in anteroposterior radiographs by means of tilt ratios.

Authors:  T Schwarz; A Benditz; H-R Springorum; J Matussek; G Heers; M Weber; T Renkawitz; J Grifka; B Craiovan
Journal:  Arch Orthop Trauma Surg       Date:  2018-04-12       Impact factor: 3.067

9.  The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Guo-Fei Sun; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Med Biol Eng Comput       Date:  2019-09-09       Impact factor: 2.602

10.  The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.

Authors:  William S Murphy; Ho Hyun Yun; Brett Hayden; Jens H Kowal; Stephen B Murphy
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

View more