Literature DB >> 21728013

Robotic assisted total hip arthroplasty using the MAKO platform.

Rupesh Tarwala1, Lawrence D Dorr.   

Abstract

Surgeons want to perform a perfect total hip replacement (THR) with every operation. Human performance has limitations, especially when performing a mechanical operation in a biological environment. Recent suggested changes to improve outcomes have been large femoral heads and anterior incisions, but unfortunately neither has resulted in any scientific data that change has been effected. The scientific data does tell us that poor component positions and impingement are the source of increasing mechanical complications. Therefore, attempts to improve the surgeon's performance by precise quantitative knowledge in the operating room have been used. We discuss robotic guided navigation as a solution. This technology provides predictable and reproducible results.

Entities:  

Year:  2011        PMID: 21728013      PMCID: PMC3261258          DOI: 10.1007/s12178-011-9086-7

Source DB:  PubMed          Journal:  Curr Rev Musculoskelet Med        ISSN: 1935-9748


  19 in total

1.  Quantification of pelvic tilt in total hip arthroplasty.

Authors:  Jinjun Zhu; Zhinian Wan; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2009-08-28       Impact factor: 4.176

2.  Wear and range of motion of different femoral head sizes.

Authors:  Eric Mark Hammerberg; Zhinian Wan; Manish Dastane; Lawrence D Dorr
Journal:  J Arthroplasty       Date:  2009-09-23       Impact factor: 4.757

3.  Comparison of total hip replacement with and without cement in patients younger than 50 years of age: the results at 18 years.

Authors:  Y H Kim; J S Kim; J W Park; J H Joo
Journal:  J Bone Joint Surg Br       Date:  2011-04

4.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

5.  Acetabular anteversion with CT in supine, simulated standing, and sitting positions in a THA patient population.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Michel Gorin; Yves Catonné; Marc Antoine Rousseau
Journal:  Clin Orthop Relat Res       Date:  2010-12-16       Impact factor: 4.176

6.  Effect of femoral component offset on polyethylene wear in total hip arthroplasty.

Authors:  D P Sakalkale; P F Sharkey; K Eng; W J Hozack; R H Rothman
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

7.  High complication rate with anterior total hip arthroplasties on a fracture table.

Authors:  Brian A Jewett; Dennis K Collis
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

8.  A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty.

Authors:  Lawrence D Dorr; Zhinian Wan; Aamer Malik; Jinjun Zhu; Manish Dastane; Prashant Deshmane
Journal:  J Bone Joint Surg Am       Date:  2009-11       Impact factor: 5.284

9.  Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note.

Authors:  J J Callaghan; E E Forest; J P Olejniczak; D D Goetz; R C Johnston
Journal:  J Bone Joint Surg Am       Date:  1998-05       Impact factor: 5.284

10.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

View more
  11 in total

1.  Incidental findings detected on preoperative CT imaging obtained for robotic-assisted joint replacements: clinical importance and the effect on the scheduled arthroplasty.

Authors:  Gary Tran; Lafi S Khalil; Allen Wrubel; Chad L Klochko; Jason J Davis; Steven B Soliman
Journal:  Skeletal Radiol       Date:  2020-11-03       Impact factor: 2.199

2.  [Application of Mako robot-assisted total hip arthroplasty in developmental dysplasia of the hip].

Authors:  Gujun Xu; Mingyang Ma; Shuai Zhang; Yubo Liu; Xiangpeng Kong; Wei Chai
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-10-15

3.  Total Hip Arthroplasty with Robotic Arm Assistance for Precise Cup Positioning: A Case-Control Study.

Authors:  Dong-Hui Guo; Xiao-Ming Li; Shi-Qiang Ma; Yun-Chao Zhao; Chao Qi; Yuan Xue
Journal:  Orthop Surg       Date:  2022-06-14       Impact factor: 2.279

4.  Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty.

Authors:  Ruoyu Wang; Xiaojing Zheng; Tianze Xu; Song Gong; Shaokai Liu; Lizhi Han; Shuhua Yang; Weihua Xu
Journal:  Front Bioeng Biotechnol       Date:  2020-08-21

5.  The Use of Computerized Tomography Scans in Elective Knee and Hip Arthroplasty-What Do They Tell Us and at What Risk?

Authors:  Taylor D'Amore; Gregg Klein; Jess Lonner
Journal:  Arthroplast Today       Date:  2022-05-05

6.  Short-term Risk of Revision THA in the Medicare Population Has Not Improved With Time.

Authors:  Kevin J Bozic; Kevin Ong; Steven Kurtz; Edmund Lau; Thomas P Vail; Harry Rubash; Daniel Berry
Journal:  Clin Orthop Relat Res       Date:  2015-09-23       Impact factor: 4.176

7.  Three-dimensional acetabular orientation measurement in a reliable coordinate system among one hundred Chinese.

Authors:  Henghui Zhang; Yiping Wang; Songtao Ai; Xiaojun Chen; Liao Wang; Kerong Dai
Journal:  PLoS One       Date:  2017-02-16       Impact factor: 3.240

8.  Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips.

Authors:  Wei Chai; Xiangpeng Kong; Minzhi Yang; Ken Lee Puah; Peifu Tang; Jiying Chen
Journal:  Ther Clin Risk Manag       Date:  2020-05-04       Impact factor: 2.423

9.  Current concepts in robotic total hip arthroplasty.

Authors:  Pascal Kouyoumdjian; Jad Mansour; Chahine Assi; Jacques Caton; Sebastien Lustig; Remy Coulomb
Journal:  SICOT J       Date:  2020-11-27

10.  Aerosol morphology and particle size distribution in orthopaedic bone machining: a laboratory worst-case contamination simulation. Is high-speed bone machining potentially harmful by pollution and quality schemes and what measures could be taken for prevention?

Authors:  David Putzer; Dietmar Dammerer; Cora Huber; Harald Boschert; Martin Thaler; Michael Nogler
Journal:  Int Orthop       Date:  2022-04-18       Impact factor: 3.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.