Abstract

UNLABELLED: Wear of highly cross-linked polyethylene is reportedly independent of head size. To confirm that observation we asked in our population whether head size related to wear with one type of electron beam highly cross-linked polyethylene. Of 146 hips implanted, we evaluated complete clinical and radiographic data for 90 patients (102 hips or 70%). The minimum followup was 5 years (mean, 5.7 years; range, 5-8 years). The head size was selected intraoperatively based on the size of the acetabular component and presumed risk of dislocation. Polyethylene wear measurements were performed in one experienced laboratory using the method of Martell et al. There was no hip with pelvic or femoral osteolysis. The median linear wear rate was 0.028 mm/year (mean, 0.04 mm/year), and the median volumetric wear rate was 25.6 mm(3)/year (mean, 80.5 mm(3)/year). Median total volumetric wear was 41.0 mm(3) (mean, 98.5 mm(3)). We found no association between femoral head size and the linear wear rate, but observed an association between larger (36- and 40-mm) head size and volumetric wear rate and total volumetric wear. Although the linear wear rate of polyethylene was not related to femoral head diameter, there was greater volumetric wear (156.6 mm(3)/year) with the 36- and 40-mm heads. Pending long-term studies of large head sizes, we advise caution in using larger femoral heads in young or active patients and in those with a low risk of dislocation. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19690932      PMCID: PMC2772909          DOI: 10.1007/s11999-009-1038-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  33 in total

1.  A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award.

Authors:  O K Muratoglu; C R Bragdon; D O O'Connor; M Jasty; W H Harris
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

2.  Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept.

Authors:  O K Muratoglu; C R Bragdon; D O'Connor; R S Perinchief; D M Estok; M Jasty; W H Harris
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

Review 3.  The importance of the normality assumption in large public health data sets.

Authors:  Thomas Lumley; Paula Diehr; Scott Emerson; Lu Chen
Journal:  Annu Rev Public Health       Date:  2001-10-25       Impact factor: 21.981

4.  Femoral head sizes larger than 32 mm against highly cross-linked polyethylene.

Authors:  Brian R Burroughs; Harry E Rubash; William H Harris
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

5.  Stability of total hip arthroplasty in patients 75 years or older.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

6.  Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty.

Authors:  Andrew J Hui; Richard W McCalden; John M Martell; Steven J MacDonald; Robert B Bourne; Cecil H Rorabeck
Journal:  J Bone Joint Surg Am       Date:  2003-03       Impact factor: 5.284

7.  The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.

Authors:  S Glyn-Jones; P McLardy-Smith; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-05

8.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

9.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

10.  Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty.

Authors:  John M Martell; Eric Berkson; Richard Berger; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

View more
  37 in total

1.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

2.  Is routine mid-term total hip arthroplasty surveillance beneficial?

Authors:  James A Keeney; Bradley S Ellison; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

3.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

5.  Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

6.  Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up.

Authors:  Matthew G Teeter; Colin J MacLean; Lyndsay E Somerville; James L Howard; Richard W McCalden; Brent A Lanting; Edward M Vasarhelyi
Journal:  J Orthop       Date:  2018-05-07

Review 7.  Hip replacement in the athlete: is there a role?

Authors:  M J Wilson; R N Villar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-12       Impact factor: 4.342

8.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

9.  [Cement-free and cemented Excia hip shaft prosthesis: comparison of intermediate term results].

Authors:  C Urschel; M Döring; W Strecker
Journal:  Orthopade       Date:  2014-09       Impact factor: 1.087

10.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.