Literature DB >> 12637439

Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty.

Andrew J Hui1, Richard W McCalden, John M Martell, Steven J MacDonald, Robert B Bourne, Cecil H Rorabeck.   

Abstract

BACKGROUND: Three-dimensional radiographic techniques have been developed to estimate in vivo polyethylene wear of total hip replacements. We are not aware of any published study examining the accuracy of these in vivo methods. Our objective was to validate two radiographic techniques by comparing their results with those obtained directly from retrieved specimens.
METHODS: A coordinate measuring machine was used to probe the interior bearing surface of seventeen acetabular liners that had been retrieved at revision surgery. Solid models were created to determine volumetric polyethylene loss and linear depth and direction of wear. Two in vivo radiographic techniques (PolyWare and the Martell Hip Analysis Suite) were used to calculate two-dimensional linear, three-dimensional linear, and volumetric wear. The radiographic analysis was done independently, and the results were compared with the known values of polyethylene wear derived with use of the coordinate measuring machine.
RESULTS: Correlation coefficients comparing the values for two-dimensional and three-dimensional linear wear and volumetric wear derived with the PolyWare radiographic technique with the values derived with the coordinate measuring machine were r(2) = 0.78, r(2) = 0.75, and r(2) = 0.91, respectively (all p < 0.001), and the correlation coefficients comparing the values derived with the Martell Hip Analysis Suite radiographic technique with those derived with the coordinate measuring machine were r(2) = 0.80, r(2) = 0.84, and r(2) = 0.91, respectively (p < 0.001). The average absolute difference between the radiographic estimates and the results derived with the coordinate measuring machine was approximately 19% (range, 13% to 24%).
CONCLUSIONS: There was good agreement between the wear estimates made with both in vivo techniques and the measurements of the retrieved polyethylene liners made with the coordinate measuring machine. Two-dimensional wear analysis (based on anteroposterior radiographs) accounted for most of the polyethylene wear, while one technique of three-dimensional wear analysis (PolyWare) demonstrated some additional wear in the lateral plane.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12637439     DOI: 10.2106/00004623-200303000-00017

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  35 in total

1.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

2.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

4.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

5.  CORR Insights®: Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA.

Authors:  Robert H Hopper
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

6.  Long-term results of uncemented acetabular cups with an ACS polyethylene liner. a 14-16-year follow-up study.

Authors:  E Garcia-Rey; E Garcia-Cimbrelo
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

7.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

8.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

9.  Can the volume of pelvic osteolysis be calculated without using computed tomography?

Authors:  Hiroshi Egawa; Cara C Powers; Sarah E Beykirch; Robert H Hopper; C Anderson Engh; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

10.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.