Literature DB >> 18450618

The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.

S Glyn-Jones1, P McLardy-Smith, H S Gill, D W Murray.   

Abstract

The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis. We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the three-dimensional penetration of the liners over three years. After three years the mean total penetration was 0.35 mm (SD 0.14) for the highly cross-linked polyethylene group and 0.45 mm (SD 0.19) for the standard group. The difference was statistically significant (p = 0.0184). From the pattern of penetration it was possible to discriminate creep from wear. Most (95%) of the creep occurred within six months of implantation and nearly all within the first year. There was no difference in the mean degree of creep between the two types of polyethylene (highly cross-linked polyethylene 0.26 mm, SD 0.17; standard 0.27 mm, SD 0.2; p = 0.83). There was, however, a significant difference (p = 0.012) in the mean wear rate (highly cross-linked polyethylene 0.03 mm/yr, SD 0.06; standard 0.07 mm/yr, SD 0.05). Creep and wear occurred in significantly different directions (p = 0.01); creep was predominantly proximal whereas wear was anterior, proximal and medial. We conclude that penetration in the first six months is creep-dominated, but after one year virtually all penetration is due to wear. Highly cross-linked polyethylene has a 60% lower rate of wear than standard polyethylene and therefore will probably perform better in the long term.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18450618     DOI: 10.1302/0301-620X.90B5.20545

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  35 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

3.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

4.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

5.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

Review 6.  A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty.

Authors:  Zongyou Mu; Jialiang Tian; Taixiang Wu; Jing Yang; Fuxing Pei
Journal:  Int Orthop       Date:  2009-01-29       Impact factor: 3.075

7.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

8.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

9.  Dislocation after total hip arthroplasty with 28 and 32-mm femoral head.

Authors:  Einar Amlie; Øystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-05-27

10.  Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery.

Authors:  Luca Pierannunzii; Florian Fischer; Marco d'Imporzano
Journal:  J Orthop Traumatol       Date:  2008-10-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.