Femoral head sizes larger than 32 mm against highly cross-linked polyethylene.

Brian R Burroughs1, Harry E Rubash, William H Harris.   

Abstract

The advent of highly cross-linked ultrahigh molecular weight polyethylene, which shows extremely low wear independent of head size in vitro, allows for the reevaluation of the use of femoral heads larger than 32 mm. The current authors discuss information that supports this hypothesis. The supporting information includes in vitro wear testing and in vitro anatomic studies, and prior clinical studies in which large femoral heads were used.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12461367     DOI: 10.1097/00003086-200212000-00018

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

1.  The Frank Stinchfield Award: Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial?

Authors:  Donald S Garbuz; Bassam A Masri; Clive P Duncan; Nelson V Greidanus; Eric R Bohm; Martin J Petrak; Craig J Della Valle; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Authors:  Adolph V Lombardi; Michael D Skeels; Keith R Berend; Joanne B Adams; Orlando J Franchi
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years.

Authors:  Remi Philippot; Jean Philippe Camilleri; Bertrand Boyer; Philippe Adam; Frederic Farizon
Journal:  Int Orthop       Date:  2008-06-03       Impact factor: 3.075

4.  The first 50 years of total hip arthroplasty: lessons learned.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2008-11-04       Impact factor: 4.176

5.  High stress conditions do not increase wear of thin highly crosslinked UHMWPE.

Authors:  Natalie H Kelly; Amar D Rajadhyaksha; Timothy M Wright; Suzanne A Maher; Geoffrey H Westrich
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

6.  What factors affect posterior dislocation distance in THA?

Authors:  Jim Nevelos; Aaron Johnson; Christopher Heffernan; James Macintyre; David C Markel; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

7.  Results of Primary Total Hip Arthroplasty with 36-mm Femoral Heads on Highly Cross-linked Polyethylene-Minimum Seven-years Follow-up.

Authors:  Won-Kee Choi; Myung-Rae Cho; Joo-Hwan Lee
Journal:  Hip Pelvis       Date:  2014-12-31

8.  Femoral head size does not affect ion values in metal-on-metal total hips.

Authors:  Mitchell Bernstein; Alan Walsh; Alain Petit; David J Zukor; Olga L Huk; John Antoniou
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

9.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

10.  Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years.

Authors:  Paul F Lachiewicz; Daniel S Heckman; Elizabeth S Soileau; Jimmi Mangla; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.