Literature DB >> 18946711

Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene.

Kevin L Garvin1, Curtis W Hartman, Jimmi Mangla, Nathan Murdoch, John M Martell.   

Abstract

UNLABELLED: Oxidized zirconium, a material with a ceramic surface on a metal substrate, and highly cross-linked polyethylene are two materials developed to reduce wear. We measured in vivo femoral head penetration in patients with these advanced bearings. We hypothesized the linear wear rates would be lower than those published for cobalt-chrome and standard polyethylene. We retrospectively reviewed a select series of 56 THAs in a relatively young, active patient population utilizing oxidized zirconium femoral heads and highly cross-linked polyethylene acetabular liners. Femoral head penetration was determined using the Martell computerized edge-detection method. All patients were available for 2-year clinical and radiographic followup. True linear wear was 4 microm/year (95% confidence intervals, +/- 59 microm/year). The early wear rates in this cohort of relatively young, active patients were low and we believe justify the continued study of these alternative bearing surfaces. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18946711      PMCID: PMC2600989          DOI: 10.1007/s11999-008-0544-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  20 in total

1.  In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty.

Authors:  David W Manning; P P Chiang; J M Martell; J O Galante; W H Harris
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

2.  Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up.

Authors:  Charles R Bragdon; Susan Barrett; John M Martell; Meridith E Greene; Henrik Malchau; William H Harris
Journal:  J Arthroplasty       Date:  2006-10       Impact factor: 4.757

3.  Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture--a case report.

Authors:  Masahiro Hasegawa; Akihiro Sudo; Atsumasa Uchida
Journal:  Acta Orthop       Date:  2006-10       Impact factor: 3.717

Review 4.  Alternative bearing surfaces for total joint arthroplasty.

Authors:  L M Jazrawi; F J Kummer; P E DiCesare
Journal:  J Am Acad Orthop Surg       Date:  1998 Jul-Aug       Impact factor: 3.020

5.  Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty.

Authors:  M Wagner; H Wagner
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

6.  Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups.

Authors:  B M Wroblewski; P D Siney; D Dowson; S N Collins
Journal:  J Bone Joint Surg Br       Date:  1996-03

7.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

8.  Modern metal on metal articulation for total hip replacements.

Authors:  L D Dorr; K R Hilton; Z Wan; G D Markovich; R Bloebaum
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

9.  Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results.

Authors:  Jeffrey A Geller; Henrik Malchau; Charles Bragdon; Meridith Greene; William H Harris; Andrew A Freiberg
Journal:  Clin Orthop Relat Res       Date:  2006-06       Impact factor: 4.176

10.  Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study.

Authors:  N Sugano; T Nishii; K Nakata; K Masuhara; K Takaoka
Journal:  J Bone Joint Surg Br       Date:  1995-07
View more
  20 in total

1.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

2.  CORR Insights(®): oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  Alexander Jaime Grübl
Journal:  Clin Orthop Relat Res       Date:  2015-09-10       Impact factor: 4.176

3.  Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.

Authors:  Amine Zaoui; Samer El Hage; Jean Langlois; Caroline Scemama; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

4.  Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  George K Karidakis; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

5.  Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.

Authors:  Kevin L Garvin; Tyler C White; Anand Dusad; Curtis W Hartman; John Martell
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

6.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

7.  Acetabular UHMWPE survival and wear changes with different manufacturing techniques.

Authors:  John B Meding; E Michael Keating; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

8.  Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement.

Authors:  Marzieh M Ardestani; Pedro P Amenábar Edwards; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2017-03-02       Impact factor: 4.176

9.  Estimating the burden of total knee replacement in the United States.

Authors:  Alexander M Weinstein; Benjamin N Rome; William M Reichmann; Jamie E Collins; Sara A Burbine; Thomas S Thornhill; John Wright; Jeffrey N Katz; Elena Losina
Journal:  J Bone Joint Surg Am       Date:  2013-03-06       Impact factor: 5.284

10.  A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty.

Authors:  Young-Hoo Kim; Jang-Won Park; Sourabh S Kulkarni; Yoon-Hong Kim
Journal:  Int Orthop       Date:  2013-08-03       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.