Literature DB >> 25443362

Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Mohamed E Moussa1, Christina I Esposito1, Marcella E Elpers1, Timothy M Wright1, Douglas E Padgett1.   

Abstract

The aims of this study were to assess damage on the surface of retrieved oxidized zirconium (OxZr) metal femoral heads, to measure surface roughness of scratches, and to evaluate the extent of surface effacement using scanning electron microscopy (SEM). Ceramic zirconia-toughened alumina heads were analyzed for comparison. OxZr femoral heads explanted for recurrent dislocation had the most severe damage (P<0.001). The median surface roughness of damaged OxZr femoral heads was 1.49μm, compared to 0.084μm for damaged ceramic heads and 0.052μm for undamaged OxZr (P<0.001). This may be of clinical concern because increased surface roughness has the potential to increase the wear of polyethylene liners articulating against these OxZr heads in THA.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bearing; dislocation; hip arthroplasty; oxidized zirconia; roughness

Mesh:

Substances:

Year:  2014        PMID: 25443362      PMCID: PMC4414690          DOI: 10.1016/j.arth.2014.10.036

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Surface damage to an Oxinium femoral head prosthesis after dislocation.

Authors:  G T Evangelista; E Fulkerson; F Kummer; P E Di Cesare
Journal:  J Bone Joint Surg Br       Date:  2007-04

2.  Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies.

Authors:  Alan M Kop; Colin Whitewood; Don J L Johnston
Journal:  J Arthroplasty       Date:  2007-04-20       Impact factor: 4.757

3.  Oxinium femoral head damage generated by a metallic foreign body within the polyethylene cup following recurrent dislocation episodes.

Authors:  E Gibon; C Scemama; B David; M Hamadouche
Journal:  Orthop Traumatol Surg Res       Date:  2013-09-23       Impact factor: 2.256

4.  Damage of an Oxinium femoral head and polyethylene liner following 'routine' total hip replacement.

Authors:  R W McCalden; K D Charron; R D Davidson; M G Teeter; D W Holdsworth
Journal:  J Bone Joint Surg Br       Date:  2011-03

5.  Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients.

Authors:  Thomas Kadar; Geir Hallan; Arild Aamodt; Kari Indrekvam; Mona Badawy; Arne Skredderstuen; Leif Ivar Havelin; Terje Stokke; Kristin Haugan; Birgitte Espehaug; Ove Furnes
Journal:  J Orthop Res       Date:  2011-02-25       Impact factor: 3.494

6.  Modeling polyethylene wear acceleration due to femoral head dislocation damage.

Authors:  Karen M Kruger; Nishant M Tikekar; Anneliese D Heiner; John J Lannutti; John J Callaghan; Thomas D Brown
Journal:  J Arthroplasty       Date:  2014-04-05       Impact factor: 4.757

7.  Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene.

Authors:  Robert B Bourne; Robert Barrack; Cecil H Rorabeck; Abraham Salehi; Victoria Good
Journal:  Clin Orthop Relat Res       Date:  2005-12       Impact factor: 4.176

8.  Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear.

Authors:  Young-Hoo Kim; Allan Ritchie; Cath Hardaker
Journal:  J Bone Joint Surg Am       Date:  2005-03       Impact factor: 5.284

9.  Oxidized zirconium versus cobalt-chromium in TKA: profilometry of retrieved femoral components.

Authors:  Thomas J Heyse; Marcella E Elpers; Danyal H Nawabi; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

10.  Advanced wear of an Oxinium™ femoral head implant following polyethylene liner dislocation.

Authors:  H Tribe; S Malek; J Stammers; V Ranawat; J A Skinner
Journal:  Ann R Coll Surg Engl       Date:  2013-11       Impact factor: 1.891

View more
  5 in total

1.  Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Alberto Carli; Chelsea N Koch; Christina I Esposito; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

2.  The Oxinium Arthrogram: A Sign of Oxidized Zirconium Implant Failure.

Authors:  Benjamin M Frye; Kelsey R Laughery; Adam E Klein
Journal:  Arthroplast Today       Date:  2021-03-07

3.  Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty.

Authors:  Matthew Jian-Qiao Peng; Hai-Yan Chen; Yong Hu; XiangYang Ju; Bo Bai
Journal:  BMC Musculoskelet Disord       Date:  2017-07-11       Impact factor: 2.362

4.  Zirconia-Toughened Alumina Coated Ti6Al4V via Additive Manufacturing.

Authors:  Jose D Avila; Amit Bandyopadhyay
Journal:  Mater Lett       Date:  2021-02-19       Impact factor: 3.423

5.  Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.

Authors:  Ryan Siskey; Lauren Ciccarelli; Melissa K C Lui; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.