Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.

Amine Zaoui1, Samer El Hage1, Jean Langlois1, Caroline Scemama1, Jean Pierre Courpied1, Moussa Hamadouche2.   

Abstract

BACKGROUND: Charnley low-friction torque total hip arthroplasty (THA) remains the gold standard in THA. The main cause for failure is wear of the socket. Highly crosslinked polyethylene (HXLPE) has been associated with reduced wear rates. Also, oxidized zirconium has shown in vitro reduced wear rates. However, to our knowledge, there are no data comparing oxidized zirconium femoral heads with metal heads against HXLPE or ultrahigh-molecular-weight polyethylene (UHMWPE) when 22.25-mm bearings were used, which was the same size that performed so well in Charnley-type THAs. QUESTIONS/PURPOSES: We hypothesized that after a minimal 4-year followup (1) use of HXLPE would result in lower radiographic wear than UHMWPE when articulating with a stainless steel head or with an oxidized zirconium head; (2) use of oxidized zirconium would result in lower radiographic wear than stainless steel when articulating with UHMWPE and HXLPE; and (3) there would be no difference in terms of Merle d'Aubigné scores between the bearing couple combinations.
METHODS: One hundred patients were randomized to receive cemented THA with either oxidized zirconium or a stainless steel femoral head. UHMWPE was used in the first 50 patients, whereas HXLPE was used in the next 50 patients. There were 25 patients in each of the four bearing couple combinations. All other parameters were identical in both groups. Complete followup was available in 86 of these patients. Femoral head penetration was measured using a validated computer-assisted method dedicated to all-polyethylene sockets. Clinical results were compared between the groups using the Merle d'Aubigné score.
RESULTS: In the UHMWPE series, the median steady-state penetration rate from 1 year onward was 0.03 mm/year (range, 0.003-0.25 mm/year) in the oxidized zirconium group versus 0.11 mm/year (range, 0.03-0.29 mm/year) in the metal group (difference of medians 0.08, p < 0.001). In the HXLPE series, the median steady-state penetration rate from 1 year onward was 0.02 mm/year (range, -0.32 to 0.07 mm/year) in the oxidized zirconium group versus 0.05 mm/year (range, -0.39 to 0.11 mm/year) in the metal group (difference of medians 0.03, p < 0.001). The Merle d'Aubigné scores were no different between the groups with a median of 18 in each of the groups (range, 16-18).
CONCLUSIONS: This study demonstrated femoral head penetration was reduced by oxidized zirconium when compared with metal on both UHMWPE and HXLPE. However, apart the metal-UHMWE group, all other groups had a steady-state penetration rate well below the osteolysis threshold with a low difference between groups that might not be clinically important at this point. Longer-term followup is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening. LEVEL OF EVIDENCE: Level II, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26113111      PMCID: PMC4626485          DOI: 10.1007/s11999-015-4414-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  24 in total

1.  A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award.

Authors:  O K Muratoglu; C R Bragdon; D O O'Connor; M Jasty; W H Harris
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

2.  Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.

Authors:  H McKellop; F W Shen; B Lu; P Campbell; R Salovey
Journal:  J Orthop Res       Date:  1999-03       Impact factor: 3.494

3.  Reduced wear with oxidized zirconium femoral heads.

Authors:  Victoria Good; Michael Ries; Robert L Barrack; Kirstin Widding; Gordon Hunter; Dan Heuer
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

Review 4.  A review of current cross-linked polyethylenes used in total joint arthroplasty.

Authors:  William H Harris; Orhun K Muratoglu
Journal:  Clin Orthop Relat Res       Date:  2005-01       Impact factor: 4.176

5.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

6.  [Numerical evaluation of hip function].

Authors:  R Merle D'Augibné
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1970 Jul-Aug

7.  Total hip arthroplasty for the treatment of ankylosed hips : a five to twenty-one-year follow-up study.

Authors:  M Hamadouche; L Kerboull; A Meunier; J P Courpied; M Kerboull
Journal:  J Bone Joint Surg Am       Date:  2001-07       Impact factor: 5.284

8.  Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components.

Authors:  Daniel J Berry; W Scott Harmsen; Miguel E Cabanela; Bernard F Morrey
Journal:  J Bone Joint Surg Am       Date:  2002-02       Impact factor: 5.284

9.  Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty.

Authors:  John M Martell; Eric Berkson; Richard Berger; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

10.  Long-term results of Charnley-Kerboull hip arthroplasty in patients younger than 50 years.

Authors:  Luc Kerboull; Moussa Hamadouche; Jean Pierre Courpied; Marcel Kerboull
Journal:  Clin Orthop Relat Res       Date:  2004-01       Impact factor: 4.176

View more
  3 in total

1.  Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up.

Authors:  Matthew G Teeter; Colin J MacLean; Lyndsay E Somerville; James L Howard; Richard W McCalden; Brent A Lanting; Edward M Vasarhelyi
Journal:  J Orthop       Date:  2018-05-07

2.  CORR Insights®: Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

3.  The Oxinium Arthrogram: A Sign of Oxidized Zirconium Implant Failure.

Authors:  Benjamin M Frye; Kelsey R Laughery; Adam E Klein
Journal:  Arthroplast Today       Date:  2021-03-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.