Literature DB >> 8981886

Modern metal on metal articulation for total hip replacements.

L D Dorr1, K R Hilton, Z Wan, G D Markovich, R Bloebaum.   

Abstract

Between 1991 and 1994, 70 patients received total hip replacements with metal on metal articulation. The results of 54 of these patients with 54 hips who have a 2- to 4-year (2.7-year average) followup are reported. Patients were prospectively evaluated using the Harris hip score, a patient self assessment form, and radiographs. Hip aspiration was performed preoperatively and 6 to 24 months postoperatively in 24 hips with metal on metal articulations. Implant retrieval was obtained from 2 patients. Harris hip score averages increased from 49 to 93. No patient had revision surgery for loosening, but 1 had revision surgery for dislocation. Patient self assessment forms showed 51 of 54 patients scored their results as good or excellent. Serial radiographs did not show loosening or osteolysis. Wear could not be measured radiographically. Synovial fluid samples had metal particles of 1 to 10 microm in 10 hips. Twenty patients had bilateral total hip replacements with 1 hip metal on polyethylene articulation, and patients could not determine any difference between the hips. Compared with historic results of previous metal on metal prostheses, the modern metal on metal articulation investigated in this study did not have early acetabular loosening or clinical symptoms of component impaction. Retrieval implants and synovial fluid analysis suggest early wear was minimal.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8981886

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model.

Authors:  Yoshihisa Kotani; Bryan W Cunningham; Kuniyoshi Abumi; Anton E Dmitriev; Niabin Hu; Manabu Ito; Yasuo Shikinami; Paul C McAfee; Akio Minami
Journal:  Eur Spine J       Date:  2006-03-22       Impact factor: 3.134

2.  Failure of the Durom Metasul acetabular component.

Authors:  William T Long; Manish Dastane; Michael J Harris; Zhinian Wan; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2009-09-02       Impact factor: 4.176

Review 3.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  Proinflammatory and osteolysis-inducing effects of 3D printing Ti6Al4V particles in vitro and in vivo.

Authors:  Cuidi Li; Chuan Jiang; Mingzheng Peng; Tao Li; Zezheng Yang; Zhiyuan Liu; Ning Li; Chengtao Wang; Kerong Dai; Jinwu Wang
Journal:  RSC Adv       Date:  2018-01-09       Impact factor: 4.036

5.  Effects of titanium particle size on osteoblast functions in vitro and in vivo.

Authors:  Moon G Choi; Hae S Koh; Daniel Kluess; Daniel O'Connor; Anshu Mathur; George A Truskey; Janet Rubin; David X F Zhou; K-L Paul Sung
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-08       Impact factor: 11.205

6.  Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.

Authors:  Ian Holloway; William L Walter; Bernie Zicat; William K Walter
Journal:  Int Orthop       Date:  2008-11-05       Impact factor: 3.075

7.  The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Authors:  Donald S Garbuz; Michael Tanzer; Nelson V Greidanus; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2009-08-21       Impact factor: 4.176

8.  Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene.

Authors:  Kevin L Garvin; Curtis W Hartman; Jimmi Mangla; Nathan Murdoch; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2008-10-23       Impact factor: 4.176

Review 9.  Material Science in Cervical Total Disc Replacement.

Authors:  Martin H Pham; Vivek A Mehta; Alexander Tuchman; Patrick C Hsieh
Journal:  Biomed Res Int       Date:  2015-10-07       Impact factor: 3.411