Literature DB >> 8769325

Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty.

M Wagner1, H Wagner.   

Abstract

Seventy uncemented stemmed total hip replacements and 35 uncemented surface replacements with all metal Metasul articulating surfaces were followed up in a prospective study. There was no evidence that this metal on metal articulation causes new problems or complications that were not known already from other polyethylene-aluminum oxide ceramic articulating combinations. The results of 64 of 70 patients could be assessed as excellent and good. When tissue samples obtained during 2 reoperations for ectopic ossification were examined histologically, there was no light microscopic evidence of metal particles. In these cases, aseptic loosening seemed to be due to the lack of initial fixation with the original femoral component design, and was not related to the use of the Metasul bearing. The metal on metal articulation reduces the production of particles considerably according to experience to date. It is therefore hoped that foreign body reactions due to wear particles will be significantly reduced. The results support the continued investigation of metal on metal joint replacements for younger, active patients.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8769325     DOI: 10.1097/00003086-199608001-00008

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  18 in total

1.  [Hip resurfacing arthroplasty].

Authors:  W-C Witzleb; A Knecht; T Beichler; T Köhler; K-P Günther
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

Review 2.  Hip resurfacing: a technology reborn.

Authors:  Steven Cutts; Paul B Carter
Journal:  Postgrad Med J       Date:  2006-12       Impact factor: 2.401

3.  [Resurfacing arthroplasty of the hip].

Authors:  M Rudert; L Gerdesmeyer; H Rechl; P Juhnke; R Gradinger
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

4.  Metal-on-metal surface hip arthroplasty in patients with abnormal Coxanatomy: preliminary results.

Authors:  H Sharma; A C Campbell; S Thajam; B J Singh
Journal:  Eur J Orthop Surg Traumatol       Date:  2005-12-13

5.  [Approach to painful hip resurfacing].

Authors:  L Gerdesmeyer; H Gollwitzer; P Diehl; M Fuerst; M Schmitt-Sody
Journal:  Orthopade       Date:  2011-06       Impact factor: 1.087

6.  Resurfacing hip arthroplasty in neuromuscular hip disorders - A retrospective case series.

Authors:  Francois Tudor; Amir Ariamanesh; Anish Potty; Aresh Hashemi-Nejad
Journal:  J Orthop       Date:  2013-08-13

7.  [Metal/metal--a new (old) hip bearing system in clinical evaluation. Prospective 7-year follow-up study].

Authors:  N Jessen; A Nickel; K Schikora; K Büttner-Janz
Journal:  Orthopade       Date:  2003-10-22       Impact factor: 1.087

Review 8.  [Development of hip resurfacing].

Authors:  H Rechl; H Pilge; M Rudert
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

9.  Serum and urine metal levels in patients with metal-on-metal surface arthroplasty.

Authors:  Anastasia K Skipor; Patricia A Campbell; Leslie M Patterson; Harlan C Anstutz; Thomas P Schmalzried; Joshua J Jacobs
Journal:  J Mater Sci Mater Med       Date:  2002-12       Impact factor: 3.896

Review 10.  Is patient selection important for hip resurfacing?

Authors:  Ryan M Nunley; Craig J Della Valle; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.