Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups.

B M Wroblewski1, P D Siney, D Dowson, S N Collins.   

Abstract

We report the findings from independent prospective clinical and laboratory-based joint-simulator studies of the performance of ceramic femoral heads of 22.225 mm diameter in cross-linked polyethylene (XLP) acetabular cups. We found remarkable qualitative and quantitative agreement between the clinical and simulator results for the wear characteristics with time, and confirmed that ceramic femoral heads penetrate the XLP cups at only about half the rate of otherwise comparable metal heads. In the clinical study, 19 hips in 17 patients were followed for an average of 77 months. In the hip-joint simulator a similar prosthesis was tested for 7.3 million cycles. Both clinical and simulator results showed relatively high rates of penetration over the first 18 months or 1.5 million cycles, followed by a very much lower wear thereafter. Once an initial bedding-in of 0.2 mm to 0.4 mm had taken place the subsequent rates of penetration were very small. The initial clinical wear during bedding-in averaged 0.29 mm/year; subsequent progression was an order of magnitude lower at about 0.022 mm/year, lower than the 0.07 mm/year in metal-to-UHMWP Charnley LFAs. Our results show the excellent tribological features of alumina-ceramic-to-XLP implants, and also confirm the value of well-designed joint simulators for the evaluation of total joint replacements.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8666642

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  15 in total

1.  Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene.

Authors:  H Marrs; D C Barton; R A Jones; I M Ward; J Fisher; C Doyle
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

2.  Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Nucl Instrum Methods Phys Res B       Date:  2007-12       Impact factor: 1.377

3.  Incidence of ceramic liner malseating in Trident acetabular shell.

Authors:  Anna N Miller; Edwin P Su; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2009-03-12       Impact factor: 4.176

4.  Quantification of clearance and creep in acetabular wear measurements.

Authors:  Mo Saffarini; Thomas Gregory; Eric Vandenbussche
Journal:  Ann Transl Med       Date:  2016-04

5.  Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene.

Authors:  Kevin J Warburton; John B Everingham; Jillian L Helms; Andrew J Kazanovicz; Katherine A Hollar; Jeff D Brourman; Steven M Fox; Trevor J Lujan
Journal:  J Orthop Res       Date:  2017-11-14       Impact factor: 3.494

6.  Acetabular UHMWPE survival and wear changes with different manufacturing techniques.

Authors:  John B Meding; E Michael Keating; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

7.  Alumina heads minimize wear and femoral osteolysis progression after isolated simple acetabular revision.

Authors:  Philippe Hernigou; Nicolas Dupuy; Olivier Pidet; Yashuhiro Homma; Charles Henri Flouzat Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

Authors:  Yup Lee Jung; Shin-Yoon Kim
Journal:  Open Orthop J       Date:  2010-02-11

9.  Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene.

Authors:  Kevin L Garvin; Curtis W Hartman; Jimmi Mangla; Nathan Murdoch; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2008-10-23       Impact factor: 4.176

10.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.