Literature DB >> 26290343

Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

George K Karidakis1, Theofilos Karachalios2.   

Abstract

BACKGROUND: Osteolysis resulting from wear debris production from the bearing surfaces is a major factor limiting long-term survival of hip implants. Oxidized zirconium head on crosslinked polyethylene (XLPE) is a modern bearing coupling. However, midterm in vivo wear data of this coupling are not known. QUESTIONS/PURPOSES: The purpose of this study was to investigate in vivo whether the combination of an oxidized zirconium femoral head on XLPE produces less wear than a ceramic head on XLPE or a ceramic head on conventional polyethylene (CPE) couplings and whether any of these bearing combinations results in higher hip scores.
METHODS: Between 2003 and 2007, we performed 356 total hip arthroplasties in 288 patients; of those, 199 (69.1%) patients (199 hips) were enrolled in what began as a randomized trial. Unfortunately, after the 57(th) patient, the randomization process was halted because of patients' preference for the oxidized zirconium bearing instead of the ceramic after (as they were informed by the consent form), and after that, alternate allocation to the study groups was performed. Hips were allocated into four groups: in Group A, a 28-mm ceramic head on CPE was used; in Group B, a 28-mm ceramic head on XLPE; in Group C, a 28-mm Oxinium head on XLPE; and in Group D, a 32-mm Oxinium head on XLPE. The authors prospectively collected in vivo wear data (linear wear, linear wear rate, volumetric wear, and volumetric wear rate) using PolyWare software. Preoperative and postoperative clinical data, including Harris and Oxford hip scores, were also collected at regular intervals. Of those patients enrolled, 188 (95%) were available for final followup at a minimum of 7 years (mean, 9 years; range, 7-12 years).
RESULTS: All bearing surfaces showed a varying high bedding-in effect (plastic deformation of the liner) up to the second postoperative year. At 5 years both oxidized zirconium on XLPE groups showed lower (p < 0.01) volumetric wear (mean ± SD mm(3)) and volumetric wear rates (mean ± SD mm(3)/year) (Group C: 310 ± 55-206 ± 55 mm(3)/year, Group D: 320 ± 58-205 ± 61 mm(3)/year) when compared with ceramic on CPE (Group A: 791 ± 124-306 ± 85 mm(3)/year) and ceramic on XLPE (Group B: 1420 ± 223-366 ± 88 mm(3)/year) groups. For those patients who had completed 10 years of followup (20 patients [44.5%] of Group A, 21 [45.7%] of Group B, 23 [47.9%] of Group C, and 22 [44.9%] of Group D), at 10 years, both oxidized zirconium on XLPE groups also showed lower (p < 0.01) volumetric wear (mean ± SD mm(3)) and volumetric wear rates (mean ± SD mm(3)/year) (Group C: 356 ± 64 to 215 ± 54 mm(3)/year, Group D: 354 ± 50 to 210 ± 64 mm(3)/year) when compared with ceramic on CPE (Group A: 895 ± 131 to 380 ± 80 mm(3)/year) and ceramic on XLPE (Group B: 1625 ± 253 to 480 ± 101 mm(3)/year) groups. When wear rates of both oxidized zirconium groups were compared, no differences were found at any time interval with the numbers available. Two hips (one from Group A and one from Group B) are scheduled for revision as a result of wear and osteolysis. There were no differences in hip scores among the groups with the numbers available.
CONCLUSIONS: In this study, in vivo wear parameters were lower when the combination of an oxidized zirconium head on XLPE liner was used at an average of 9 years (range, 7-12 years) followup. Further larger-scale clinical studies should confirm these findings and evaluate osteolysis and revision rates in association with the use of this bearing coupling. LEVEL OF EVIDENCE: Level II, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26290343      PMCID: PMC4626474          DOI: 10.1007/s11999-015-4503-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  44 in total

1.  Assessment of polyethylene wear in total hip replacement.

Authors:  P A Devane; J G Horne
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

2.  On the material and the tribology of alumina-alumina couplings for hip joint prostheses.

Authors:  A Walter
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

3.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

4.  In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty.

Authors:  David W Manning; P P Chiang; J M Martell; J O Galante; W H Harris
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

5.  Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture--a case report.

Authors:  Masahiro Hasegawa; Akihiro Sudo; Atsumasa Uchida
Journal:  Acta Orthop       Date:  2006-10       Impact factor: 3.717

6.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

7.  Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique.

Authors:  P A Devane; R B Bourne; C H Rorabeck; R M Hardie; J G Horne
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

8.  A 12- to 18-year radiographic follow-up study of Charnley low-friction arthroplasty. The role of the center of rotation.

Authors:  T Karachalios; G Hartofilakidis; N Zacharakis; M Tsekoura
Journal:  Clin Orthop Relat Res       Date:  1993-11       Impact factor: 4.176

9.  Comparative outcomes of total joint arthroplasty.

Authors:  M A Ritter; M J Albohm; E M Keating; P M Faris; J B Meding
Journal:  J Arthroplasty       Date:  1995-12       Impact factor: 4.757

10.  Health and quality of life before and after hip or knee arthroplasty.

Authors:  P Rissanen; S Aro; P Slätis; H Sintonen; P Paavolainen
Journal:  J Arthroplasty       Date:  1995-04       Impact factor: 4.757

View more
  8 in total

Review 1.  New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.

Authors:  Preston W Grieco; Scott Pascal; Jared M Newman; Neil V Shah; Sarah G Stroud; Neil P Sheth; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-27

2.  Editor's Spotlight/Take 5: Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Seth S Leopold
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

3.  Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Alberto Carli; Chelsea N Koch; Christina I Esposito; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

4.  The Oxinium Arthrogram: A Sign of Oxidized Zirconium Implant Failure.

Authors:  Benjamin M Frye; Kelsey R Laughery; Adam E Klein
Journal:  Arthroplast Today       Date:  2021-03-07

5.  An Unusual Central Dislocation of a Total Hip Arthroplasty Due to Severe Wear of a Ceramic on Cross-linked Polyethylene Bearing Coupling - A Case Report.

Authors:  Efstratios Athanaselis; George Komnos; Theofilos Karachalios
Journal:  J Orthop Case Rep       Date:  2018 Nov-Dec

6.  Partially randomised patient preference trials as an alternative design to randomised controlled trials: systematic review and meta-analyses.

Authors:  Karin A Wasmann; Pieta Wijsman; Susan van Dieren; Willem Bemelman; Christianne Buskens
Journal:  BMJ Open       Date:  2019-10-16       Impact factor: 2.692

7.  Long-term Results of Primary Hip Arthroplasty with Cup Inclination Angle Bigger than Fifty Degrees.

Authors:  Jialiang Tian; Li Sun; Ruiyin Hu; Wei Han; Xiaobin Tian
Journal:  J Clin Orthop Trauma       Date:  2017-04-20

8.  Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty.

Authors:  Alberto V Carli; Anay R Patel; Michael B Cross; David J Mayman; Kaitlin M Carroll; Paul M Pellicci; Seth A Jerabek
Journal:  SICOT J       Date:  2020-05-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.