Literature DB >> 16741475

Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results.

Jeffrey A Geller1, Henrik Malchau, Charles Bragdon, Meridith Greene, William H Harris, Andrew A Freiberg.   

Abstract

Contemporary highly cross-linked polyethylenes have become the most widely used alternative bearing surfaces in total hip replacement and may be paired with large diameter femoral heads (> 32 mm) in patients considered to be at high risk for dislocation. We report on a prospective series of 42 patients (45 hips) who had total hip replacement using large diameter cobalt-chrome femoral heads articulating with a highly cross linked polyethylene after a minimum of 3 years followup (mean 3.3 years). At final followup, the final patient cohort showed excellent clinical results with no radiographic failures or episodes of loosening. There was no evidence of pelvic or femoral osteolysis. One patient sustained a dislocation due to a grossly malpositioned acetabular component necessitating early isolated acetabular revision. The average yearly steady state wear rate was -0.06 +/- 0.41 mm/year. The results of our short-term prospective series indicated total hip replacement with large femoral heads articulating with a highly cross linked polyethylene showed excellent wear characteristics and clinical results and could be considered in patients at increased risk for dislocation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16741475     DOI: 10.1097/01.blo.0000218742.61624.80

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  The Frank Stinchfield Award: Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial?

Authors:  Donald S Garbuz; Bassam A Masri; Clive P Duncan; Nelson V Greidanus; Eric R Bohm; Martin J Petrak; Craig J Della Valle; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Authors:  Adolph V Lombardi; Michael D Skeels; Keith R Berend; Joanne B Adams; Orlando J Franchi
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital.

Authors:  Sebastian S Mukka; Sarwar S Mahmood; Göran O Sjödén; Arkan S Sayed-Noor
Journal:  Orthop Rev (Pavia)       Date:  2013-06-11

4.  A cadaveric study of posterior dislocation after total hip replacement-effects of head diameter and acetabular anteversion.

Authors:  Fu Yuen Ng; Jiang Tao Zhang; Kwong Yuen Chiu; Chun Hoi Yan
Journal:  Int Orthop       Date:  2010-02-24       Impact factor: 3.075

5.  Results of Primary Total Hip Arthroplasty with 36-mm Femoral Heads on Highly Cross-linked Polyethylene-Minimum Seven-years Follow-up.

Authors:  Won-Kee Choi; Myung-Rae Cho; Joo-Hwan Lee
Journal:  Hip Pelvis       Date:  2014-12-31

6.  The unstable total hip replacement.

Authors:  F D'Angelo; L Murena; G Zatti; P Cherubino
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

7.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

Review 8.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25

9.  Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years.

Authors:  Paul F Lachiewicz; Daniel S Heckman; Elizabeth S Soileau; Jimmi Mangla; John M Martell
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

10.  Activities of daily living after total hip arthroplasty. Is a 32-mm femoral head superior to a 26-mm head for improving daily activities?

Authors:  Isao Matsushita; Yuji Morita; Yoshiaki Ito; Ryuichi Gejo; Tomoatsu Kimura
Journal:  Int Orthop       Date:  2009-11-29       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.