Literature DB >> 18780135

Use of a dual mobility socket to manage total hip arthroplasty instability.

Olivier Guyen1, Vincent Pibarot, Gualter Vaz, Christophe Chevillotte, Jacques Béjui-Hugues.   

Abstract

UNLABELLED: Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2-6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2008        PMID: 18780135      PMCID: PMC2628522          DOI: 10.1007/s11999-008-0476-0

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  60 in total

Review 1.  Dislocation after total hip arthroplasty.

Authors:  Maximillian Soong; Harry E Rubash; William Macaulay
Journal:  J Am Acad Orthop Surg       Date:  2004 Sep-Oct       Impact factor: 3.020

2.  Dislocation following total hip arthroplasty.

Authors:  B Kristiansen; L Jørgensen; P Hölmich
Journal:  Arch Orthop Trauma Surg       Date:  1985

3.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

4.  Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem.

Authors:  J R Loudon; J Charnley
Journal:  J Bone Joint Surg Br       Date:  1980-11

5.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

6.  Femoral component loosening using contemporary techniques of femoral cement fixation.

Authors:  W H Harris; J C McCarthy; D A O'Neill
Journal:  J Bone Joint Surg Am       Date:  1982-09       Impact factor: 5.284

7.  Classification and treatment of dislocations of total hip arthroplasty.

Authors:  L D Dorr; A W Wolf; R Chandler; J P Conaty
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

8.  Dislocations after total hip arthroplasty.

Authors:  R Y Woo; B F Morrey
Journal:  J Bone Joint Surg Am       Date:  1982-12       Impact factor: 5.284

9.  Recurrent dislocation after total hip replacement. Treatment by fixing an additional sector to the acetabular component.

Authors:  S Olerud; G Karlström
Journal:  J Bone Joint Surg Br       Date:  1985-05

10.  Dislocation following total hip replacement.

Authors:  M A Ali Khan; P H Brakenbury; I S Reynolds
Journal:  J Bone Joint Surg Br       Date:  1981
View more
  55 in total

1.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

Review 2.  [What can be done when hip prostheses fail? : New trends in revision endoprosthetics].

Authors:  S Gravius; T Randau; D C Wirtz
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

3.  Is a cementless dual mobility socket in primary THA a reasonable option?

Authors:  Moussa Hamadouche; Hervé Arnould; Bertrand Bouxin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  The use of a cemented dual mobility socket to treat recurrent dislocation.

Authors:  Moussa Hamadouche; David J Biau; Denis Huten; Thierry Musset; François Gaucher
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 5.  Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.

Authors:  Christian Fabry; Jean Langlois; Moussa Hamadouche; Rainer Bader
Journal:  Int Orthop       Date:  2015-10-01       Impact factor: 3.075

6.  Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital.

Authors:  Sebastian S Mukka; Sarwar S Mahmood; Göran O Sjödén; Arkan S Sayed-Noor
Journal:  Orthop Rev (Pavia)       Date:  2013-06-11

7.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

Review 8.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

Review 9.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

10.  [Bone defect adjusted strategy in revision arthroplasty of the hip : Wich implant in wich situation? Innovations and approved methods].

Authors:  B S Craiovan; J Grifka; A Keshmiri; B Moser; M Wörner; T Renkawitz
Journal:  Orthopade       Date:  2015-05       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.