Literature DB >> 7118973

Femoral component loosening using contemporary techniques of femoral cement fixation.

W H Harris, J C McCarthy, D A O'Neill.   

Abstract

A radiographic study was done of 171 total hip replacements that had been followed for an average of 3.3 years (range, two to five years). The study was performed to assess the incidence of loosening of the femoral component in older adult patients (average age, sixty years) in whom the medullary canal had been plugged with methylmethacrylate (using the medullary plug syringe to introduce the plug) prior to introducing the cement (Simplex P) with a cement-gun. Most of the femoral components that were used were of the CAD or HD-2 design, and all were made of chromium-cobalt alloy. Three categories of loosening were defined: definite (requiring radiographic evidence of migration of the component or the cement), probable (requiring evidence of complete 100 per cent radiolucent zone around the cement mantle on one or more radiographs), and possible (requiring evidence of a radiolucent zone that occupied more than 50 but less than 100 per cent of the cement-bone interface on one or more radiographs). One hip required revision for a loose femoral component and another patient had asymptomatic subsidence of the femoral component. Thus, the total incidence of definitely loose femoral components was 1.1 per cent. No hip was classified as having probable loosening; seven hips (4 per cent) were rated as having possible loosening. Compared with the results of four other published reports of patients of similar age with similar follow-up, and using the same radiographic criterion for loosening, the current series demonstrated a statistically significant reduction in the incidence of definitely loose femoral components.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7118973

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  72 in total

1.  Early aseptic loosening of cemented total hip arthroplasty: the influence of non-steroidal anti-inflammatory drugs and smoking.

Authors:  M H A Malik; J Gray; P R Kay
Journal:  Int Orthop       Date:  2004-03-27       Impact factor: 3.075

2.  A scoring system to determine radiological loosening in cemented total hip arthroplasty.

Authors:  D M Dall; I D Learmonth; M Solomon
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

3.  [Replacement of femoral hip prostheses].

Authors:  M Rudert; M Hoberg; P M Prodinger; R Gradinger; B M Holzapfel
Journal:  Chirurg       Date:  2010-04       Impact factor: 0.955

4.  Is two-stage reimplantation effective for virulent pathogenic infection in a periprosthetic hip? A retrospective analysis.

Authors:  Yong-Cheol Yoon; Devendra Lakhotia; Jong-Keon Oh; Jun Gyu Moon; Kumar Prashant; Won Yong Shon
Journal:  World J Orthop       Date:  2015-10-18

5.  Current attitudes to total hip replacement in the younger patient: results of a national survey.

Authors:  T D Tennent; N J Goddard
Journal:  Ann R Coll Surg Engl       Date:  2000-01       Impact factor: 1.891

6.  [Effect of femoral cementing technique on results. Comparison between retrograde technique and vacuum application].

Authors:  S Ungethuem; B Lehner; T Reitzel; P J Buckley; H Mau; S J Breusch
Journal:  Orthopade       Date:  2005-07       Impact factor: 1.087

7.  Prediction of Charnley femoral stem aseptic loosening by early post-operative radiological features.

Authors:  M H A Malik; N Fisher; J Gray; B M Wroblewski; P R Kay
Journal:  Int Orthop       Date:  2005-08-05       Impact factor: 3.075

8.  Custom total hip arthroplasty in skeletal dysplasia.

Authors:  Liza Osagie; Mark Figgie; Mathias Bostrom
Journal:  Int Orthop       Date:  2011-07-13       Impact factor: 3.075

9.  Polyethylene and highly cross-linked polyethylene for cemented total hip arthroplasty: A comparison of over ten-year clinical and radiographic results.

Authors:  Tomotoshi Kawata; Koji Goto; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2017-08-10

10.  Genetic susceptibility to hip arthroplasty failure--association with the RANK/OPG pathway.

Authors:  M H A Malik; A Bayat; F Jury; W E R Ollier; P R Kay
Journal:  Int Orthop       Date:  2006-04-01       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.