Literature DB >> 18072512

Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT.

Jiayu Song1, Qing H Liu, G Allan Johnson, Cristian T Badea.   

Abstract

Recent advances in murine cardiac studies with three-dimensional (3D) cone beam micro-CT used a retrospective gating technique. However, this sampling technique results in a limited number of projections with an irregular angular distribution due to the temporal resolution requirements and radiation dose restrictions. Both angular irregularity and undersampling complicate the reconstruction process, since they cause significant streaking artifacts. This work provides an iterative reconstruction solution to address this particular challenge. A sparseness prior regularized weighted l2 norm optimization is proposed to mitigate streaking artifacts based on the fact that most medical images are compressible. Total variation is implemented in this work as the regularizer for its simplicity. Comparison studies are conducted on a 3D cardiac mouse phantom generated with experimental data. After optimization, the method is applied to in vivo cardiac micro-CT data.

Entities:  

Mesh:

Year:  2007        PMID: 18072512      PMCID: PMC2366112          DOI: 10.1118/1.2795830

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography.

Authors:  M Persson; D Bone; H Elmqvist
Journal:  Phys Med Biol       Date:  2001-03       Impact factor: 3.609

2.  Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing.

Authors:  Patrick J La Rivière; David M Billmire
Journal:  IEEE Trans Med Imaging       Date:  2005-01       Impact factor: 10.048

3.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

4.  Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice.

Authors:  Maria Drangova; Nancy L Ford; Sarah A Detombe; Andrew R Wheatley; David W Holdsworth
Journal:  Invest Radiol       Date:  2007-02       Impact factor: 6.016

5.  Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware.

Authors:  Marc Kachelriess; Michael Knaup; Olivier Bockenbach
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

6.  Micro-CT with respiratory and cardiac gating.

Authors:  C Badea; L W Hedlund; G A Johnson
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

7.  4-D micro-CT of the mouse heart.

Authors:  Cristian T Badea; Boma Fubara; Laurence W Hedlund; G Allan Johnson
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

8.  Development of a 4-D digital mouse phantom for molecular imaging research.

Authors:  William P Segars; Benjamin M W Tsui; Eric C Frey; G Allan Johnson; Stuart S Berr
Journal:  Mol Imaging Biol       Date:  2004 May-Jun       Impact factor: 3.488

9.  Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields.

Authors:  Paul J Cassidy; Jürgen E Schneider; Stuart M Grieve; Craig Lygate; Stefan Neubauer; Kieran Clarke
Journal:  J Magn Reson Imaging       Date:  2004-02       Impact factor: 4.813

10.  Fast, high-resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system.

Authors:  Jürgen E Schneider; Paul J Cassidy; Craig Lygate; Damian J Tyler; Frank Wiesmann; Stuart M Grieve; Karen Hulbert; Kieran Clarke; Stefan Neubauer
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

View more
  62 in total

1.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  A dual micro-CT system for small animal imaging.

Authors:  C T Badea; S Johnston; B Johnson; M Lin; L W Hedlund; G Allan Johnson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-04-18

3.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT.

Authors:  Emil Y Sidky; Yuval Duchin; Xiaochuan Pan; Christer Ullberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  Simultaneous segmentation and reconstruction: a level set method approach for limited view computed tomography.

Authors:  Sungwon Yoon; Angel R Pineda; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

6.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

7.  Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

Authors:  Cristian T Badea; Samuel M Johnston; Ergys Subashi; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

8.  Iterative image reconstruction for CBCT using edge-preserving prior.

Authors:  Jing Wang; Tianfang Li; Lei Xing
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

9.  Image reconstruction for sparse-view CT and interior CT-introduction to compressed sensing and differentiated backprojection.

Authors:  Hiroyuki Kudo; Taizo Suzuki; Essam A Rashed
Journal:  Quant Imaging Med Surg       Date:  2013-06

10.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.