Prior image constrained compressed sensing: implementation and performance evaluation.

Pascal Thériault Lauzier1, Jie Tang, Guang-Hong Chen.   

Abstract

PURPOSE: Prior image constrained compressed sensing (PICCS) is an image reconstruction framework which incorporates an often available prior image into the compressed sensing objective function. The images are reconstructed using an optimization procedure. In this paper, several alternative unconstrained minimization methods are used to implement PICCS. The purpose is to study and compare the performance of each implementation, as well as to evaluate the performance of the PICCS objective function with respect to image quality.
METHODS: Six different minimization methods are investigated with respect to convergence speed and reconstruction accuracy. These minimization methods include the steepest descent (SD) method and the conjugate gradient (CG) method. These algorithms require a line search to be performed. Thus, for each minimization algorithm, two line searching algorithms are evaluated: a backtracking (BT) line search and a fast Newton-Raphson (NR) line search. The relative root mean square error is used to evaluate the reconstruction accuracy. The algorithm that offers the best convergence speed is used to study the performance of PICCS with respect to the prior image parameter α and the data consistency parameter λ. PICCS is studied in terms of reconstruction accuracy, low-contrast spatial resolution, and noise characteristics. A numerical phantom was simulated and an animal model was scanned using a multirow detector computed tomography (CT) scanner to yield the projection datasets used in this study.
RESULTS: For λ within a broad range, the CG method with Fletcher-Reeves formula and NR line search offers the fastest convergence for an equal level of reconstruction accuracy. Using this minimization method, the reconstruction accuracy of PICCS was studied with respect to variations in α and λ. When the number of view angles is varied between 107, 80, 64, 40, 20, and 16, the relative root mean square error reaches a minimum value for α ≈ 0.5. For values of α near the optimal value, the spatial resolution of the reconstructed image remains relatively constant and the noise texture is very similar to that of the prior image, which was reconstructed using the filtered backprojection (FBP) algorithm.
CONCLUSIONS: Regarding the performance of the minimization methods, the nonlinear CG method with NR line search yields the best convergence speed. Regarding the performance of the PICCS image reconstruction, three main conclusions can be reached. (1) The performance of PICCS is optimal when the weighting parameter of the prior image parameter is selected to be near α = 0.5. (2) The spatial resolution measured for static objects in images reconstructed using PICCS from undersampled datasets is not degraded with respect to the fully-sampled reconstruction for α near its optimal value. (3) The noise texture of PICCS reconstructions is similar to that of the prior image, which was reconstructed using the conventional FBP method.

Mesh:

Year:  2012        PMID: 22225276      PMCID: PMC3257752          DOI: 10.1118/1.3666946

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies.

Authors:  Jie Tang; Jiang Hsieh; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  Convergence of the simultaneous algebraic reconstruction technique (SART).

Authors:  Ming Jiang; Ge Wang
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

4.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results.

Authors:  Brian E Nett; Robert Brauweiler; Willi Kalender; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2010-04-01       Impact factor: 3.609

7.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

8.  Performance studies of four-dimensional cone beam computed tomography.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2011-09-30       Impact factor: 3.609

9.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more
  32 in total

1.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.

Authors:  Guang-Hong Chen; Yinsheng Li
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

Authors:  Yinsheng Li; John W Garrett; Ke Li; Charles Strother; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2019-12-20       Impact factor: 10.048

3.  Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med       Date:  2020-04-28       Impact factor: 2.685

4.  Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR).

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Benjamin J Cooper; Zdenka Kuncic; Paul J Keall
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

5.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

6.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

7.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data.

Authors:  Kerstin Müller; Chris Schwemmer; Joachim Hornegger; Yefeng Zheng; Yang Wang; Günter Lauritsch; Christopher Rohkohl; Andreas K Maier; Carl Schultz; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

9.  Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT.

Authors:  K Müller; A K Maier; C Schwemmer; G Lauritsch; S De Buck; J-Y Wielandts; J Hornegger; R Fahrig
Journal:  Phys Med Biol       Date:  2014-05-20       Impact factor: 3.609

10.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.

Authors:  Junguo Bian; Jiong Wang; Xiao Han; Emil Y Sidky; Lingxiong Shao; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.