Literature DB >> 20175466

Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

Cristian T Badea1, Samuel M Johnston, Ergys Subashi, Yi Qi, Laurence W Hedlund, G Allan Johnson.   

Abstract

PURPOSE: Quantitative in vivo imaging of lung perfusion in rodents can provide critical information for preclinical studies. However, the combined challenges of high temporal and spatial resolution have made routine quantitative perfusion imaging difficult in small animals. The purpose of this work is to demonstrate 4D micro-CT for perfusion imaging in rodents at heartbeat temporal resolution and isotropic spatial resolution.
METHODS: We have recently developed a dual tube/detector micro-CT scanner that is well suited to capture first pass kinetics of a bolus of contrast agent used to compute perfusion information. Our approach is based on the paradigm that similar time density curves can be reproduced in a number of consecutive, small volume injections of iodinated contrast agent at a series of different angles. This reproducibility is ensured by the high-level integration of the imaging components of our system with a microinjector, a mechanical ventilator, and monitoring applications. Sampling is controlled through a biological pulse sequence implemented in LABVIEW. Image reconstruction is based on a simultaneous algebraic reconstruction technique implemented on a graphic processor unit. The capabilities of 4D micro-CT imaging are demonstrated in studies on lung perfusion in rats.
RESULTS: We report 4D micro-CT imaging in the rat lung with a heartbeat temporal resolution (approximately 150 ms) and isotropic 3D reconstruction with a voxel size of 88 microm based on sampling using 16 injections of 50 microL each. The total volume of contrast agent injected during the experiments (0.8 mL) was less than 10% of the total blood volume in a rat. This volume was not injected in a single bolus, but in multiple injections separated by at least 2 min interval to allow for clearance and adaptation. We assessed the reproducibility of the time density curves with multiple injections and found that these are very similar. The average time density curves for the first eight and last eight injections are slightly different, i.e., for the last eight injections, both the maximum of the average time density curves and its area under the curve are decreased by 3.8% and 7.2%, respectively, relative to the average time density curves based on the first eight injections. The radiation dose associated with our 4D micro-CT imaging is 0.16 Gy and is therefore in the range of a typical micro-CT dose.
CONCLUSIONS: 4D micro-CT-based perfusion imaging demonstrated here has immediate application in a wide range of preclinical studies such as tumor perfusion, angiogenesis, and renal function. Although our imaging system is in many ways unique, we believe that our approach based on the multiple injection paradigm can be used with the newly developed flat-panel slip-ring-based micro-CT to increase their temporal resolution in dynamic perfusion studies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20175466      PMCID: PMC2801733          DOI: 10.1118/1.3264619

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware.

Authors:  K Mueller; R Yagel
Journal:  IEEE Trans Med Imaging       Date:  2000-12       Impact factor: 10.048

Review 2.  Review article: Effects of radiographic contrast media on the lung.

Authors:  S K Morcos
Journal:  Br J Radiol       Date:  2003-05       Impact factor: 3.039

Review 3.  Mechanical ventilation for imaging the small animal lung.

Authors:  Laurence W Hedlund; G Allan Johnson
Journal:  ILAR J       Date:  2002

4.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

Authors:  L Ostergaard; R M Weisskoff; D A Chesler; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

5.  Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT.

Authors:  André Constantinesco; Philippe Choquet; Laurent Monassier; Vincent Israel-Jost; Luc Mertz
Journal:  J Nucl Med       Date:  2005-06       Impact factor: 10.057

Review 6.  Autonomic control of blood pressure in mice: basic physiology and effects of genetic modification.

Authors:  Ben J A Janssen; Jos F M Smits
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2002-06       Impact factor: 3.619

7.  Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.

Authors:  Ming De Lin; Greta Toncheva; Giao Nguyen; Sangroh Kim; Colin Anderson-Evans; G Allan Johnson; Terry T Yoshizumi
Journal:  Radiat Res       Date:  2008-08       Impact factor: 2.841

8.  Development of a 4-D digital mouse phantom for molecular imaging research.

Authors:  William P Segars; Benjamin M W Tsui; Eric C Frey; G Allan Johnson; Stuart S Berr
Journal:  Mol Imaging Biol       Date:  2004 May-Jun       Impact factor: 3.488

9.  Assessment of tumor blood perfusion by high-resolution dynamic contrast-enhanced MRI: a preclinical study of human melanoma xenografts.

Authors:  Ilana C Benjaminsen; Bjørn A Graff; Kjetil G Brurberg; Einar K Rofstad
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

10.  Fast, high-resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system.

Authors:  Jürgen E Schneider; Paul J Cassidy; Craig Lygate; Damian J Tyler; Frank Wiesmann; Stuart M Grieve; Karen Hulbert; Kieran Clarke; Stefan Neubauer
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

View more
  11 in total

1.  Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response.

Authors:  Fabian Eisa; Robert Brauweiler; Martin Hupfer; Tristan Nowak; Laura Lotz; Inge Hoffmann; David Wachter; Ralf Dittrich; Matthias W Beckmann; Gregor Jost; Hubertus Pietsch; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-11-10       Impact factor: 5.315

Review 2.  Applications of imaging technology in radiation research.

Authors:  MingDe Lin; Edward F Jackson
Journal:  Radiat Res       Date:  2012-03-08       Impact factor: 2.841

3.  Cerebral CT perfusion using an interventional C-arm imaging system: cerebral blood flow measurements.

Authors:  A Ganguly; A Fieselmann; M Marks; J Rosenberg; J Boese; Y Deuerling-Zheng; M Straka; G Zaharchuk; R Bammer; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

4.  Dual-energy micro-CT of the rodent lung.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C D Marshall; C A Piantadosi
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2012-03-16       Impact factor: 5.464

5.  Magnetic resonance imaging of disease progression and resolution in a transgenic mouse model of pulmonary fibrosis.

Authors:  Zackary I Cleveland; Yu M Zhou; Teckla G Akinyi; R Scott Dunn; Cynthia R Davidson; Jinbang Guo; Jason C Woods; William D Hardie
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2017-01-27       Impact factor: 5.464

6.  4D micro-CT for cardiac and perfusion applications with view under sampling.

Authors:  Cristian T Badea; Samuel M Johnston; Yi Qi; G Allan Johnson
Journal:  Phys Med Biol       Date:  2011-05-10       Impact factor: 3.609

7.  Robust dynamic myocardial perfusion CT deconvolution for accurate residue function estimation via adaptive-weighted tensor total variation regularization: a preclinical study.

Authors:  Dong Zeng; Changfei Gong; Zhaoying Bian; Jing Huang; Xinyu Zhang; Hua Zhang; Lijun Lu; Shanzhou Niu; Zhang Zhang; Zhengrong Liang; Qianjin Feng; Wufan Chen; Jianhua Ma
Journal:  Phys Med Biol       Date:  2016-10-26       Impact factor: 3.609

8.  Studies of a prototype linear stationary x-ray source for tomosynthesis imaging.

Authors:  P R Schwoebel; John M Boone; Joe Shao
Journal:  Phys Med Biol       Date:  2014-04-17       Impact factor: 3.609

9.  Temporal and spectral imaging with micro-CT.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.506

10.  Whole-organ CT perfusion of the pancreas: impact of iterative reconstruction on image quality, perfusion parameters and radiation dose in 256-slice CT-preliminary findings.

Authors:  Qian Xie; Juan Wu; Ying Tang; Yafang Dou; Sijie Hao; Feijia Xu; Xiaoyuan Feng; Zonghui Liang
Journal:  PLoS One       Date:  2013-11-26       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.