Literature DB >> 19235393

Iterative image reconstruction for CBCT using edge-preserving prior.

Jing Wang1, Tianfang Li, Lei Xing.   

Abstract

On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.

Entities:  

Mesh:

Year:  2009        PMID: 19235393      PMCID: PMC2739313          DOI: 10.1118/1.3036112

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  32 in total

1.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  Speedup OS-EM Image Reconstruction by PC Graphics Card Technologies for Quantitative SPECT with Varying Focal-Length Fan-Beam Collimation.

Authors:  Zigang Wang; Guoping Han; Tianfang Li; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2005-10       Impact factor: 1.679

3.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

4.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.

Authors:  Tianfang Li; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-29       Impact factor: 7.038

5.  Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

6.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

8.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

9.  Enhanced 4D cone-beam CT with inter-phase motion model.

Authors:  Tianfang Li; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

10.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

View more
  58 in total

1.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

4.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

5.  Penalized maximum likelihood reconstruction for improved microcalcification detection in breast tomosynthesis.

Authors:  Mini Das; Howard C Gifford; J Michael O'Connor; Stephen J Glick
Journal:  IEEE Trans Med Imaging       Date:  2010-10-28       Impact factor: 10.048

6.  Introduction: a brief overview of iterative algorithms in X-ray computed tomography.

Authors:  M Soleimani; T Pengpen
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

7.  Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation.

Authors:  Hao Yan; Xiaoyu Wang; Feng Shi; Ti Bai; Michael Folkerts; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

8.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

9.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

10.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.