Literature DB >> 17024831

Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Jing Wang1, Tianfang Li, Hongbing Lu, Zhengrong Liang.   

Abstract

Reconstructing low-dose X-ray computed tomography (CT) images is a noise problem. This work investigated a penalized weighted least-squares (PWLS) approach to address this problem in two dimensions, where the WLS considers first- and second-order noise moments and the penalty models signal spatial correlations. Three different implementations were studied for the PWLS minimization. One utilizes a Markov random field (MRF) Gibbs functional to consider spatial correlations among nearby detector bins and projection views in sinogram space and minimizes the PWLS cost function by iterative Gauss-Seidel algorithm. Another employs Karhunen-Loève (KL) transform to de-correlate data signals among nearby views and minimizes the PWLS adaptively to each KL component by analytical calculation, where the spatial correlation among nearby bins is modeled by the same Gibbs functional. The third one models the spatial correlations among image pixels in image domain also by a MRF Gibbs functional and minimizes the PWLS by iterative successive over-relaxation algorithm. In these three implementations, a quadratic functional regularization was chosen for the MRF model. Phantom experiments showed a comparable performance of these three PWLS-based methods in terms of suppressing noise-induced streak artifacts and preserving resolution in the reconstructed images. Computer simulations concurred with the phantom experiments in terms of noise-resolution tradeoff and detectability in low contrast environment. The KL-PWLS implementation may have the advantage in terms of computation for high-resolution dynamic low-dose CT imaging.

Mesh:

Year:  2006        PMID: 17024831      PMCID: PMC1619874          DOI: 10.1109/42.896783

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  15 in total

Review 1.  Fast spatio-temporal image reconstruction for dynamic PET.

Authors:  M N Wernick; E J Infusino; M Milosević
Journal:  IEEE Trans Med Imaging       Date:  1999-03       Impact factor: 10.048

2.  Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography.

Authors:  P Sukovic; N H Clinthorne
Journal:  IEEE Trans Med Imaging       Date:  2000-11       Impact factor: 10.048

3.  Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing.

Authors:  Patrick J La Rivière; David M Billmire
Journal:  IEEE Trans Med Imaging       Date:  2005-01       Impact factor: 10.048

4.  Penalized-likelihood sinogram smoothing for low-dose CT.

Authors:  Patrick J La Rivière
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

5.  Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography.

Authors:  D L Snyder; M I Miller; L J Thomas; D G Politte
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

6.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Nonstationary filtering of transmission tomograms in high photon counting noise.

Authors:  K Sauer; B Liu
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

Review 8.  ROC methodology in radiologic imaging.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1986-09       Impact factor: 6.016

9.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

10.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

View more
  120 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

5.  Virtual colonoscopy vs optical colonoscopy.

Authors:  Zhengrong Liang; Robert Richards
Journal:  Expert Opin Med Diagn       Date:  2010-03-01

6.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

7.  Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Kevin M Brown; Stanislav Zabic; Nilgoun Raihani; Jun Miao; David L Wilson
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

8.  A Feasibility Study of Extracting Tissue Textures From a Previous Full-Dose CT Database as Prior Knowledge for Bayesian Reconstruction of Current Low-Dose CT Images.

Authors:  Yongfeng Gao; Zhengrong Liang; William Moore; Hao Zhang; Marc J Pomeroy; John A Ferretti; Thomas V Bilfinger; Jianhua Ma; Hongbing Lu
Journal:  IEEE Trans Med Imaging       Date:  2019-01-03       Impact factor: 10.048

9.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

10.  New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Nucl Sci       Date:  2013-01-11       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.