Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Kihwan Choi1, Jing Wang, Lei Zhu, Tae-Suk Suh, Stephen Boyd, Lei Xing.   

Abstract

PURPOSE: This article considers the problem of reconstructing cone-beam computed tomography (CBCT) images from a set of undersampled and potentially noisy projection measurements.
METHODS: The authors cast the reconstruction as a compressed sensing problem based on l1 norm minimization constrained by statistically weighted least-squares of CBCT projection data. For accurate modeling, the noise characteristics of the CBCT projection data are used to determine the relative importance of each projection measurement. To solve the compressed sensing problem, the authors employ a method minimizing total-variation norm, satisfying a prespecified level of measurement consistency using a first-order method developed by Nesterov.
RESULTS: The method converges fast to the optimal solution without excessive memory requirement, thanks to the method of iterative forward and back-projections. The performance of the proposed algorithm is demonstrated through a series of digital and experimental phantom studies. It is found a that high quality CBCT image can be reconstructed from undersampled and potentially noisy projection data by using the proposed method. Both sparse sampling and decreasing x-ray tube current (i.e., noisy projection data) lead to the reduction of radiation dose in CBCT imaging.
CONCLUSIONS: It is demonstrated that compressed sensing outperforms the traditional algorithm when dealing with sparse, and potentially noisy, CBCT projection views.

Mesh:

Year:  2010        PMID: 20964231      PMCID: PMC2945747          DOI: 10.1118/1.3481510

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  33 in total

1.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation.

Authors:  Yong Yang; Eduard Schreibmann; Tianfang Li; Chuang Wang; Lei Xing
Journal:  Phys Med Biol       Date:  2007-01-12       Impact factor: 3.609

2.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.

Authors:  Xiangyang Tang; Jiang Hsieh; Roy A Nilsen; Sandeep Dutta; Dmitry Samsonov; Akira Hagiwara
Journal:  Phys Med Biol       Date:  2006-01-25       Impact factor: 3.609

5.  Improved k-t BLAST and k-t SENSE using FOCUSS.

Authors:  Hong Jung; Jong Chul Ye; Eung Yeop Kim
Journal:  Phys Med Biol       Date:  2007-05-10       Impact factor: 3.609

6.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

7.  Exact reconstruction of volumetric images in reverse helical cone-beam CT.

Authors:  Seungryong Cho; Dan Xia; Charles A Pelizzari; Xiaochuan Pan
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

8.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

9.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more
  49 in total

1.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT.

Authors:  Emil Y Sidky; Yuval Duchin; Xiaochuan Pan; Christer Ullberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  On the computational implementation of forward and back-projection operations for cone-beam computed tomography.

Authors:  Davood Karimi; Rabab Ward
Journal:  Med Biol Eng Comput       Date:  2015-10-05       Impact factor: 2.602

4.  Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle-Pock algorithm.

Authors:  Emil Y Sidky; Jakob H Jørgensen; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-04-27       Impact factor: 3.609

5.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

6.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

7.  Compressed sensing of spatial electron paramagnetic resonance imaging.

Authors:  David H Johnson; Rizwan Ahmad; Guanglong He; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

8.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

9.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.

Authors:  Junguo Bian; Jiong Wang; Xiao Han; Emil Y Sidky; Lingxiong Shao; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

10.  Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; William Moore; Zhengrong Liang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.