Literature DB >> 15651615

Micro-CT with respiratory and cardiac gating.

C Badea1, L W Hedlund, G A Johnson.   

Abstract

Cardiopulmonary imaging in rodents using micro-computed tomography (CT) is a challenging task due to both cardiac and pulmonary motion and the limited fluence rate available from micro-focus x-ray tubes of most commercial systems. Successful imaging in the mouse requires recognition of both the spatial and temporal scales and their impact on the required fluence rate. Smaller voxels require an increase in the total number of photons (integrated fluence) used in the reconstructed image for constant signal-to-noise ratio. The faster heart rates require shorter exposures to minimize cardiac motion blur imposing even higher demands on the fluence rate. We describe a system with fixed tube/detector and with a rotating specimen. A large focal spot x-ray tube capable of producing high fluence rates with short exposure times was used. The geometry is optimized to match focal spot blur with detector pitch and the resolution limits imposed by the reproducibility of gating. Thus, it is possible to achieve isotropic spatial resolution of 100 microm with a fluence rate at the detector 250 times that of a conventional cone beam micro-CT system with rotating detector and microfocal x-ray tube. Motion is minimized for any single projection with 10 ms exposures that are synchronized to both cardiac and breathing motion. System performance was validated in vivo by studies of the cardiopulmonary structures in C57BL/6 mice, demonstrating the value of motion integration with a bright x-ray source.

Entities:  

Mesh:

Year:  2004        PMID: 15651615      PMCID: PMC1357396          DOI: 10.1118/1.1812604

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

Review 1.  Mechanical ventilation for imaging the small animal lung.

Authors:  Laurence W Hedlund; G Allan Johnson
Journal:  ILAR J       Date:  2002

2.  In vivo respiratory-gated micro-CT imaging in small-animal oncology models.

Authors:  Dawn Cavanaugh; Evan Johnson; Roger E Price; Jonathan Kurie; Elizabeth L Travis; Dianna D Cody
Journal:  Mol Imaging       Date:  2004-01       Impact factor: 4.488

3.  Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT.

Authors:  S M Jorgensen; O Demirkaya; E L Ritman
Journal:  Am J Physiol       Date:  1998-09

Review 4.  A rapid-gated cine MRI technique.

Authors:  G H Glover; N J Pelc
Journal:  Magn Reson Annu       Date:  1988

5.  MR microscopy of the rat lung using projection reconstruction.

Authors:  S L Gewalt; G H Glover; L W Hedlund; G P Cofer; J R MacFall; G A Johnson
Journal:  Magn Reson Med       Date:  1993-01       Impact factor: 4.668

6.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

7.  Gated multiplanar cardiac computed tomography.

Authors:  G A Johnson; J D Godwin; E K Fram
Journal:  Radiology       Date:  1982-10       Impact factor: 11.105

8.  Ventilation-synchronous magnetic resonance microscopy of pulmonary structure and ventilation in mice.

Authors:  Ben T Chen; Alexander T Yordanov; G Allan Johnson
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

9.  Cardiac MRI of the normal and hypertrophied mouse heart.

Authors:  S E Slawson; B B Roman; D S Williams; A P Koretsky
Journal:  Magn Reson Med       Date:  1998-06       Impact factor: 4.668

10.  Rapid identification and 3D reconstruction of complex cardiac malformations in transgenic mouse embryos using fast gradient echo sequence magnetic resonance imaging.

Authors:  Jürgen E Schneider; Simon D Bamforth; Cassandra R Farthing; Kieran Clarke; Stefan Neubauer; Shoumo Bhattacharya
Journal:  J Mol Cell Cardiol       Date:  2003-02       Impact factor: 5.000

View more
  63 in total

1.  A dual micro-CT system for small animal imaging.

Authors:  C T Badea; S Johnston; B Johnson; M Lin; L W Hedlund; G Allan Johnson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-04-18

2.  Multibeam field emission x-ray system with half-scan reconstruction algorithm.

Authors:  Yang Lu; Hengyong Yu; Guohua Cao; Jun Zhao; Ge Wang; Otto Zhou
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

3.  Cone-beam micro-CT system based on LabVIEW software.

Authors:  Ciprian N Ionita; Keneth R Hoffmann; Daniel R Bednarek; Ravishankar Chityala; Stephen Rudin
Journal:  J Digit Imaging       Date:  2007-02-28       Impact factor: 4.056

4.  Tomographic digital subtraction angiography for lung perfusion estimation in rodents.

Authors:  Cristian T Badea; Laurence W Hedlund; Ming De Lin; Julie S Boslego Mackel; Ehsan Samei; G Allan Johnson
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

5.  A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice.

Authors:  Scott Shofer; Cristian Badea; Scott Auerbach; David A Schwartz; G Allan Johnson
Journal:  Exp Lung Res       Date:  2007 Apr-May       Impact factor: 2.459

6.  Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

Authors:  Richard Taschereau; Patrick L Chow; Arion F Chatziioannou
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

7.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

8.  Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice.

Authors:  Cristian T Badea; Laurence W Hedlund; Julie F Boslego Mackel; Lan Mao; Howard A Rockman; G Allan Johnson
Journal:  Mol Imaging       Date:  2007 Jul-Aug       Impact factor: 4.488

9.  A micro-CT analysis of murine lung recruitment in bleomycin-induced lung injury.

Authors:  Scott Shofer; Cristian Badea; Yi Qi; Erin Potts; W Michael Foster; G Allan Johnson
Journal:  J Appl Physiol (1985)       Date:  2008-06-19

10.  The utility of micro-CT and MRI in the assessment of longitudinal growth of liver metastases in a preclinical model of colon carcinoma.

Authors:  Prachi Pandit; Samuel M Johnston; Yi Qi; Jennifer Story; Rendon Nelson; G Allan Johnson
Journal:  Acad Radiol       Date:  2013-04       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.