Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice.

Maria Drangova1, Nancy L Ford, Sarah A Detombe, Andrew R Wheatley, David W Holdsworth.   

Abstract

OBJECTIVE: We sought to demonstrate retrospectively gated dynamic 3D cardiac micro computed tomography (CT) of free-breathing mice.
MATERIALS AND METHODS: Five C57Bl6 mice were scanned using a cone-beam scanner with a slip-ring-mounted flat-panel detector. After the injection of an intravascular iodinated contrast agent, projection images were acquired over the course of 50 seconds, while the scanner rotated through 10 complete rotations. The mouse respiratory and electrocardiogram signals were recorder simultaneously with image acquisition. After acquisition, the projection images were retrospectively sorted into projections belonging to different cardiac time points, occurring only during expiration.
RESULTS: Dynamic 3D cardiac images, with isotropic 150-microm voxel spacing, were reconstructed at 12-millisecond intervals throughout the cardiac cycle in all mice. The average ejection fraction and cardiac output were 58.2+/-4.6% and 11.4+/-1.3 mL/min, respectively. The measured entrance dose for the entire scan was 28 cGy. Repeat scans of the same animals showed that intrasubject variability was smaller than intersubject variability.
CONCLUSIONS: We have developed a high-resolution micro computed tomography method for evaluating the cardiac function and morphology of free-breathing mice in acquisition times shorter than 1 minute.

Entities:  

Mesh:

Year:  2007        PMID: 17220726     DOI: 10.1097/01.rli.0000251572.56139.a3

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  26 in total

1.  Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent.

Authors:  Cristian T Badea; Arthur W Wetzel; Nilesh Mistry; Stuart Pomerantz; Demian Nave; G Allan Johnson
Journal:  Comput Med Imaging Graph       Date:  2008-04       Impact factor: 4.790

2.  In vivo microCT imaging of rodent cerebral vasculature.

Authors:  Youngho Seo; Tomoki Hashimoto; Yoshitsugu Nuki; Bruce H Hasegawa
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

3.  Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Authors:  M Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

4.  Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats.

Authors:  Cristian T Badea; Laurence W Hedlund; James Cook; Brian R Berridge; G Allan Johnson
Journal:  J Pharmacol Toxicol Methods       Date:  2010-04-23       Impact factor: 1.950

5.  Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; Howard A Rockman; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

6.  Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization.

Authors:  Darin Clark; Alexandra Badea; Yilin Liu; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-09-13       Impact factor: 3.609

7.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

8.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

9.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT.

Authors:  Jiayu Song; Qing H Liu; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

10.  A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating.

Authors:  Cristian T Badea; Eduard Schreibmann; Tim Fox
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.