Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers.

K Clarke1, D A Taberner, J M Thomson, J A Morris, L Poller.   

Abstract

An attempt was made to correct for the effects of coagulometers on the International Sensitivity Index (ISI) in a series of collaborative studies. Modified ISI were derived from the prothrombin time results with coagulometer systems using a range of calibrated plasmas. Two alternative approaches to correction of the ISI were evaluated. The first relied on the consensus orthogonal regression slopes of the prothrombin times for each coagulometer system plotted against the consensus manual results; the second depended on the local individual slope of the prothrombin times for each instrument. The two procedures were compared with the currently recommended method where International Normalised Ratios (INR) are derived from the manual ISI of the thromboplastin. The recommended method gave a significant bias from the manual results with most coagulometers. In contrast, the local correction procedure gave no significant biases, whereas the consensus method did so in a few instances. Both these correction procedures seem more reliable than the recommended method of INR derivation, but the local correction is more accurate and offers a more practical solution by allowing laboratories to determine their own corrected ISI on a range of calibrated plasmas.

Mesh:

Substances:

Year:  1992        PMID: 1740517      PMCID: PMC495818          DOI: 10.1136/jcp.45.1.58

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  7 in total

1.  The dependence of the International Sensitivity Index on the coagulometer used to perform the prothrombin time.

Authors:  M J Ray; I R Smith
Journal:  Thromb Haemost       Date:  1990-06-28       Impact factor: 5.249

2.  Automation and prothrombin time: a United Kingdom field study of two widely used coagulometers.

Authors:  J M Thomson; D A Taberner; L Poller
Journal:  J Clin Pathol       Date:  1990-08       Impact factor: 3.411

3.  The effect of some instruments for prothrombin time testing on the International Sensitivity Index (ISI) of two rabbit tissue thromboplastin reagents.

Authors:  M Poggio; A M van den Besselaar; E A van der Velde; R M Bertina
Journal:  Thromb Haemost       Date:  1989-11-24       Impact factor: 5.249

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Automated versus manual techniques for the prothrombin time test: results of proficiency assessment studies.

Authors:  L Poller; J M Thomson; K F Yee
Journal:  Br J Haematol       Date:  1978-03       Impact factor: 6.998

6.  Effect of thromboplastin and instrumentation on the prothrombin time test.

Authors:  B L Evatt; D Brogan; D Triplett; J Koepke; G Waters
Journal:  Clin Lab Haematol       Date:  1981

7.  Effect of automation on prothrombin time test in NEQAS surveys.

Authors:  L Poller; J M Thomson; D A Taberner
Journal:  J Clin Pathol       Date:  1989-01       Impact factor: 3.411

  7 in total
  8 in total

1.  Screening INR deviation of local prothrombin time systems.

Authors:  L Poller
Journal:  J Clin Pathol       Date:  1998-05       Impact factor: 3.411

2.  Multicentre evaluation of the Thrombotest International Sensitivity Index used with a steel ball coagulometer.

Authors:  A M van den Besselaar; R H Peters
Journal:  J Clin Pathol       Date:  1996-05       Impact factor: 3.411

3.  Local INR correction: justification for a simplified approach.

Authors:  S Craig; K J Stevenson; J M Dufty; D A Taberner
Journal:  J Clin Pathol       Date:  1997-09       Impact factor: 3.411

4.  Calculation of System International Sensitivity Index: how many calibrant plasmas are required?

Authors:  J M Dufty; S Craig; K J Stevenson; D A Taberner
Journal:  J Clin Pathol       Date:  1997-01       Impact factor: 3.411

5.  An easier alternative to orthogonal regression for calculation of International Sensitivity Indexes.

Authors:  D A Taberner; J M Dufty
Journal:  J Clin Pathol       Date:  1995-10       Impact factor: 3.411

6.  The effects of freeze drying and freeze drying additives on the prothrombin time and the international sensitivity index.

Authors:  L Poller; M Keown; S A Shepherd; C R Shiach; S Tabeart
Journal:  J Clin Pathol       Date:  1999-10       Impact factor: 3.411

7.  Effect of thromboplastin and coagulometer interaction on the precision of the International Normalised Ratio.

Authors:  D W Pi; J M Raboud; C Filby; C J Carter
Journal:  J Clin Pathol       Date:  1995-01       Impact factor: 3.411

8.  The importance of "like to like" ISI calibrations with freeze dried plasmas. European Concerted Action on Anticoagulation.

Authors:  L Poller; A M van den Besselaar; J Jespersen; A Tripodi; D Houghton
Journal:  J Clin Pathol       Date:  1998-04       Impact factor: 3.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.