Multicentre evaluation of the Thrombotest International Sensitivity Index used with a steel ball coagulometer.

A M van den Besselaar1, R H Peters.   

Abstract

AIM: To compare the International Sensitivity Index (ISI) of the Thrombotest reagent used with a steel ball coagulometer (KC) to the ISI of the same reagent used with the manual (tilt tube) technique.
METHODS: The study was carried out by eight laboratories using their own KC instrument and method of testing. All laboratories used the same batch of Thrombotest to determine the clotting times of fresh blood samples from 20 local healthy volunteers and 60 patients on long term oral anticoagulant therapy. KC clotting times were plotted against manual clotting times on double logarithmic scales. Orthogonal regression lines were calculated to assess the ISI.
RESULTS: In two laboratories the ISI of the KC method was lower than that of the manual method; these differences, however, were 2% or less. In the other laboratories no clinically important differences were observed between ISI values obtained. However, the clotting times determined with the KC methods were shorter than the manual values.
CONCLUSIONS: The ISI of Thrombotest determined with the KC methods was very similar to the manual value. Therefore, use of the ISI value supplied by the manufacturer without adjustment is justified. The mean normal prothrombin time, however, must be determined locally.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8707959      PMCID: PMC500484          DOI: 10.1136/jcp.49.5.414

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  19 in total

1.  The effect of some instruments for prothrombin time testing on the International Sensitivity Index (ISI) of two rabbit tissue thromboplastin reagents.

Authors:  M Poggio; A M van den Besselaar; E A van der Velde; R M Bertina
Journal:  Thromb Haemost       Date:  1989-11-24       Impact factor: 5.249

2.  Quality control and oral anticoagulation.

Authors:  F E Preston
Journal:  Thromb Haemost       Date:  1995-07       Impact factor: 5.249

3.  A collaborative calibration study of reference materials for thromboplastins.

Authors:  J Hermans; A M van den Besselaar; E A Loeliger; E A van der Velde
Journal:  Thromb Haemost       Date:  1983-10-31       Impact factor: 5.249

4.  The correction of coagulometer effects on international normalized ratios: a multicentre evaluation.

Authors:  L Poller; J M Thomson; D A Taberner; D K Clarke
Journal:  Br J Haematol       Date:  1994-01       Impact factor: 6.998

5.  [Evaluation of the KC10 semi-automatic modular clot detection device].

Authors:  B Crespo; A Ankri; C Lesty
Journal:  Nouv Rev Fr Hematol       Date:  1983

6.  International Committee for Standardization in Haematology, International Committee on Thrombosis and Haemostasis: ICSH/ICTH recommendations for reporting prothrombin time in oral anticoagulant control.

Authors: 
Journal:  Thromb Haemost       Date:  1985-02-18       Impact factor: 5.249

7.  Use of lyophilized calibration plasmas and control blood for international normalized ratio calculation in external quality assessment of the prothrombin time.

Authors:  A M van den Besselaar
Journal:  Am J Clin Pathol       Date:  1994-07       Impact factor: 2.493

8.  A Multi-centre study to evaluate method dependency of the international sensitivity index of bovine thromboplastin.

Authors:  R H Peters; A M van den Besselaar; F M Olthuis
Journal:  Thromb Haemost       Date:  1989-04-25       Impact factor: 5.249

9.  Correction of instrument- and reagent-based differences in determination of the International Normalized Ratio (INR) for monitoring anticoagulant therapy.

Authors:  J L van Rijn; N A Schmidt; W P Rutten
Journal:  Clin Chem       Date:  1989-05       Impact factor: 8.327

10.  Effect of automation on prothrombin time test in NEQAS surveys.

Authors:  L Poller; J M Thomson; D A Taberner
Journal:  J Clin Pathol       Date:  1989-01       Impact factor: 3.411

View more
  1 in total

1.  Screening INR deviation of local prothrombin time systems.

Authors:  L Poller
Journal:  J Clin Pathol       Date:  1998-05       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.