Automation and prothrombin time: a United Kingdom field study of two widely used coagulometers.

J M Thomson1, D A Taberner, L Poller.   

Abstract

Current performance in the prothrombin time (PT) of the two main United Kingdom coagulometer/thromboplastin systems was assessed in a field survey. Twenty abnormal samples covering a wide spectrum of International Normalised Ratio (INR) were distributed to users of the KC4/KC10 and Coag-a-Mate instruments. Coagulometer results were compared with those of the manual method. A substantial minority with each system showed good agreement with the manual reference values. There was, however, a considerable variation between instruments, meaningful in clinical terms, evidenced by varying regression slopes and local system International Sensitivity Indices (ISI). For intense anticoagulation (3.0 to 4.5 INR) a larger dose of warfarin is needed with the Coag-a-Mate than with the KC instruments. With a manual INR of 4.0 the KC instruments tended to give longer PT (mean INR + 0.3); the Coag-a-Mate PT was generally shorter (mean INR -0.1). With both systems the mean normal PT were shorter than the manual but the degree of shortening did not parallel that of the abnormal samples. This effect undermines the use of a simple prothrombin ratio and of an INR value derived from it, based on a manual ISI. The use of a system related ISI cannot, however, be recommended until local instrument variables are controlled.

Entities:  

Mesh:

Year:  1990        PMID: 2401737      PMCID: PMC502654          DOI: 10.1136/jcp.43.8.679

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  4 in total

1.  Survey of prothrombin time in National External Quality Assessment Scheme exercises (1980-87).

Authors:  L Poller; D A Taberner; J M Thomson; K V Darby
Journal:  J Clin Pathol       Date:  1988-04       Impact factor: 3.411

2.  Comparison of two automated coagulometers and the manual tilt-tube method for the determination of prothrombin time.

Authors:  A D'Angelo; M P Seveso; S V D'Angelo; F Gilardoni; A Macagni; C Manotti; P Bonini
Journal:  Am J Clin Pathol       Date:  1989-09       Impact factor: 2.493

3.  Effect of international sensitivity index (ISI) of thromboplastins on precision of international normalised ratios (INR)

Authors:  D A Taberner; L Poller; J M Thomson; K V Darby
Journal:  J Clin Pathol       Date:  1989-01       Impact factor: 3.411

4.  Effect of automation on prothrombin time test in NEQAS surveys.

Authors:  L Poller; J M Thomson; D A Taberner
Journal:  J Clin Pathol       Date:  1989-01       Impact factor: 3.411

  4 in total
  7 in total

1.  Comparison of two different ecarin clotting time methods.

Authors:  Tivadar Fenyvesi; Job Harenberg; Christel Weiss; Ingrid Jörg
Journal:  J Thromb Thrombolysis       Date:  2005-08       Impact factor: 2.300

Review 2.  Oral anticoagulant therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Walter Ageno; Alexander S Gallus; Ann Wittkowsky; Mark Crowther; Elaine M Hylek; Gualtiero Palareti
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

3.  Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers.

Authors:  K Clarke; D A Taberner; J M Thomson; J A Morris; L Poller
Journal:  J Clin Pathol       Date:  1992-01       Impact factor: 3.411

4.  Statistical analysis of comparison between laboratory methods.

Authors:  D G Altman
Journal:  J Clin Pathol       Date:  1991-08       Impact factor: 3.411

5.  Effect of thromboplastin and coagulometer interaction on the precision of the International Normalised Ratio.

Authors:  D W Pi; J M Raboud; C Filby; C J Carter
Journal:  J Clin Pathol       Date:  1995-01       Impact factor: 3.411

6.  Factors affecting the maintenance dose of warfarin.

Authors:  A H James; R P Britt; C L Raskino; S G Thompson
Journal:  J Clin Pathol       Date:  1992-08       Impact factor: 3.411

7.  Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study.

Authors:  Michael Nagler; Lucas M Bachmann; Lorenzo Alberio; Anne Angelillo-Scherrer; Lars M Asmis; Wolfgang Korte; Adriana Mendez; Guido Reber; Hans Stricker; Dimitrios A Tsakiris; Walter A Wuillemin
Journal:  Thromb J       Date:  2013-03-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.