Effect of automation on prothrombin time test in NEQAS surveys.

L Poller1, J M Thomson, D A Taberner.   

Abstract

The performance of coagulometers in the National Quality Assessment Scheme (NEQAS) surveys of the prothrombin time conducted between 1986 and 1987 was reviewed. There were sufficient data for analysis for eight types of coagulometer used with a single type of thromboplastin reagent and one instrument with an alternative reagent. The overall reliability efficacy of each instrument was evaluated by determining the orthogonal regression slope parameters for prothrombin time (PT) and international normalised ratios (INR) using the manual technique as the reference method. Seven of the eight types of coagulometer tended to overestimate the INR. A pattern frequently observed with coagulometers, and difficult to regulate, was a trend to underestimate INR below 3.0 and overestimate higher INR. Overestimation of INR values over 3.0 was particularly pronounced with three types of instrument (Fibrintimer, Lancer, KC4/10). The KC4/10 was used by a sufficient number of participants to permit analysis of the performance of individual instruments. Within instrument differences were similar to those produced by different types of coagulometers. Thromboplastin reagents affected the INR values obtained with coagulometers. The study indicates that each local reagent-instrument combination must be calibrated by the participant to obtain reliable INR values. The use of a general correction factor for a local PT system seems to be invalid owing to the considerable variation in performance of individual coagulometers. The two best guides to the choice of coagulometer may be the deviation from the manual result and precision estimated by the coefficient of variation of the INR.

Entities:  

Mesh:

Year:  1989        PMID: 2921350      PMCID: PMC1141800          DOI: 10.1136/jcp.42.1.97

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  1 in total

1.  Automated versus manual techniques for the prothrombin time test: results of proficiency assessment studies.

Authors:  L Poller; J M Thomson; K F Yee
Journal:  Br J Haematol       Date:  1978-03       Impact factor: 6.998

  1 in total
  10 in total

Review 1.  Oral anticoagulant therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Walter Ageno; Alexander S Gallus; Ann Wittkowsky; Mark Crowther; Elaine M Hylek; Gualtiero Palareti
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

2.  Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers.

Authors:  K Clarke; D A Taberner; J M Thomson; J A Morris; L Poller
Journal:  J Clin Pathol       Date:  1992-01       Impact factor: 3.411

3.  Automation and prothrombin time: a United Kingdom field study of two widely used coagulometers.

Authors:  J M Thomson; D A Taberner; L Poller
Journal:  J Clin Pathol       Date:  1990-08       Impact factor: 3.411

4.  Screening INR deviation of local prothrombin time systems.

Authors:  L Poller
Journal:  J Clin Pathol       Date:  1998-05       Impact factor: 3.411

5.  Multicentre evaluation of the Thrombotest International Sensitivity Index used with a steel ball coagulometer.

Authors:  A M van den Besselaar; R H Peters
Journal:  J Clin Pathol       Date:  1996-05       Impact factor: 3.411

6.  Manual and automated prothrombin time tests.

Authors:  D J Easton
Journal:  J Clin Pathol       Date:  1989-10       Impact factor: 3.411

7.  ISI value of thromboplastin.

Authors:  A M Van den Besselaar
Journal:  J Clin Pathol       Date:  1989-10       Impact factor: 3.411

8.  Effect of international sensitivity index (ISI) of thromboplastins on precision of international normalised ratios (INR)

Authors:  D A Taberner; L Poller; J M Thomson; K V Darby
Journal:  J Clin Pathol       Date:  1989-01       Impact factor: 3.411

9.  United Kingdom external quality assessment in blood coagulation: the first 21 years.

Authors:  L Poller
Journal:  J Clin Pathol       Date:  1989-01       Impact factor: 3.411

10.  Effect of thromboplastin and coagulometer interaction on the precision of the International Normalised Ratio.

Authors:  D W Pi; J M Raboud; C Filby; C J Carter
Journal:  J Clin Pathol       Date:  1995-01       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.