OBJECTIVE: To evaluate the radiation-dose-reduction potential of automatic exposure control (AEC) in 16-slice and 64-slice multislice computed tomography (MSCT) of the coronary arteries (computed tomography angiography, CTA) in patients. The rapid growth in MSCT CTA emphasises the necessity of adjusting technique factors to reduce radiation dose exposure.
DESIGN: A retrospective data analysis was performed for 154 patients who had undergone MSCT CTA. Group 1 (n = 56) had undergone 16-slice MSCT without AEC, and group 2 (n = 51), with AEC. In group 1, invasive coronary angiography (ICA) had been performed in addition. Group 3 (n = 47) had been examined using a 64-slice scanner (with AEC, without ECG-triggered tube current modulation).
RESULTS: In group 1, the mean (SD) effective dose (ED) for MSCT CTA was 9.76 (1.84) mSv and for ICA it was 2.6 (1.27) mSv. In group 2, the mean ED for MSCT CTA was 5.83 (1.73) mSv, which signifies a 42.8% dose reduction for CTA by the use of AEC. In comparison to ICA, MSCT CTA without AEC shows a 3.8-fold increase in radiation dose, and the radiation dose of CTA with AEC was increased by a factor of 1.9. In group 3, the mean ED for MSCT CTA was 13.58 (2.80) mSV.
CONCLUSIONS: This is the first study to show the significant dose-reduction potential (42.8%) of AEC in MSCT CTA in patients. This relatively new technique can be used to optimise the radiation dose levels in MSCT CTA.

Entities:  

Mesh:

Year:  2007        PMID: 17395667      PMCID: PMC1955015          DOI: 10.1136/hrt.2006.103838

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  28 in total

1.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

Review 2.  Computed tomography radiation dose optimization: scanning protocols and clinical applications of automatic exposure control.

Authors:  Mannudeep K Kalra; Nausheen Naz; Stefania M R Rizzo; Michael A Blake
Journal:  Curr Probl Diagn Radiol       Date:  2005 Sep-Oct

3.  Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart.

Authors:  T Flohr; B Ohnesorge
Journal:  J Comput Assist Tomogr       Date:  2001 Nov-Dec       Impact factor: 1.826

4.  Chest CT performed with z-axis modulation: scanning protocol and radiation dose.

Authors:  Mannudeep K Kalra; Stefania Rizzo; Michael M Maher; Elkan F Halpern; Thomas L Toth; Jo-Anne O Shepard; Suzanne L Aquino
Journal:  Radiology       Date:  2005-10       Impact factor: 11.105

5.  The association between coronary calcification assessed by electron beam computed tomography and measures of extracoronary atherosclerosis: the Rotterdam Coronary Calcification Study.

Authors:  Hok-Hay S Oei; Rozemarijn Vliegenthart; A Elisabeth Hak; Antonio Iglesias del Sol; Albert Hofman; Matthijs Oudkerk; Jacqueline C M Witteman
Journal:  J Am Coll Cardiol       Date:  2002-06-05       Impact factor: 24.094

6.  Effective dose to a patient undergoing coronary angiography.

Authors:  H Lobotessi; A Karoussou; V Neofotistou; A Louisi; V Tsapaki
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

7.  Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography.

Authors:  Gilbert L Raff; Michael J Gallagher; William W O'Neill; James A Goldstein
Journal:  J Am Coll Cardiol       Date:  2005-08-02       Impact factor: 24.094

8.  Calculation of effective dose.

Authors:  C H McCollough; B A Schueler
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

9.  Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients.

Authors:  Stephen Schroeder; Andreas F Kopp; Axel Kuettner; Christof Burgstahler; Christian Herdeg; Martin Heuschmid; Andreas Baumbach; Claus D Claussen; Karl R Karsch; Ludger Seipel
Journal:  Clin Imaging       Date:  2002 Mar-Apr       Impact factor: 1.605

10.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

View more
  22 in total

1.  Coronary computed tomography angiography in coronary artery disease.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  World J Cardiol       Date:  2011-09-26

2.  Multislice CT angiography in coronary artery disease: Technical developments, radiation dose and diagnostic value.

Authors:  Zhonghua Sun
Journal:  World J Cardiol       Date:  2010-10-26

Review 3.  Coronary CT angiography: Dose reduction strategies.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

4.  Non-invasive coronary angiography: the clinical value of multi-slice computed tomography in the assessment of patients with prior coronary bypass surgery. Evaluating grafts and native vessels.

Authors:  Helge von Kiedrowski; Marcus Wiemer; Krista Franzke; Rainer Preuss; Bernhard Vaske; Thomas Butz; Olaf Oldenburg; Thomas Bitter; Khalid Mahmood; Wolfram Burchert; Dieter Horstkotte; Christoph Langer
Journal:  Int J Cardiovasc Imaging       Date:  2008-09-01       Impact factor: 2.357

5.  Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose.

Authors:  Sebastian Leschka; Paul Stolzmann; Florian T Schmid; Hans Scheffel; Bjoern Stinn; Borut Marincek; Hatem Alkadhi; Simon Wildermuth
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

6.  Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol.

Authors:  Jiyeon Lim; Eun-Ah Park; Whal Lee; Hackjoon Shim; Jin Wook Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-01-22       Impact factor: 2.357

7.  High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.

Authors:  Sonja Gordic; Daniela B Husarik; Lotus Desbiolles; Sebastian Leschka; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-11       Impact factor: 2.357

8.  [Coronary CT angiography using prospective ECG triggering: high diagnostic accuracy with low radiation dose].

Authors:  E Arnoldi; I Ramos-Duran; J A Abro; P L Zwerner; K Nikolaou; M F Reiser; P Costello; U J Schoepf
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

9.  Evolution of coronary computed tomography radiation dose reduction at a tertiary referral center.

Authors:  Brian Burns Ghoshhajra; Leif-Christopher Engel; Gyöngyi Petra Major; Alexander Goehler; Tust Techasith; Daniel Verdini; Synho Do; Bob Liu; Xinhua Li; Michiel Sala; Mi Sung Kim; Ron Blankstein; Priyanka Prakash; Manavjot S Sidhu; Erin Corsini; Dahlia Banerji; David Wu; Suhny Abbara; Quynh Truong; Thomas J Brady; Udo Hoffmann; Manudeep Kalra
Journal:  Am J Med       Date:  2012-06-15       Impact factor: 4.965

10.  Imaging coronary and extracoronary atherosclerosis: feasibility and impact of whole-body computed tomography angiography.

Authors:  Alessandro Napoli; Carlo Catalano; Marco Francone; Vincenzo Sciacca; Iacopo Carbone; Cesare Greco; Michele Anzidei; Francesca Antonella Calabrese; Beatrice Cavallo Marincola; Miles A Kirchin; Annarita Vestri; Marcello Arca; Luigi Iuliano; Roberto Passariello
Journal:  Eur Radiol       Date:  2009-03-11       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.