PURPOSE: We aimed to assess the temporal change in radiation doses from coronary computed tomography angiography (CCTA) during a 6-year period. High CCTA radiation doses have been reduced by multiple technologies that, if used appropriately, can decrease exposures significantly. METHODS: A total of 1277 examinations performed from 2005 to 2010 were included. Univariate and multivariable regression analysis of patient- and scan-related variables was performed with estimated radiation dose as the main outcome measure. RESULTS: Median doses decreased by 74.8% (P<.001), from 13.1 millisieverts (mSv) (interquartile range 9.3-14.7) in period 1 to 3.3 mSv (1.8-6.7) in period 4. Factors associated with greatest dose reductions (P<.001) were all most frequently applied in period 4: axial-sequential acquisition (univariate: -8.0 mSv [-9.7 to -7.9]), high-pitch helical acquisition (univariate: -8.8 mSv [-9.3 to -7.9]), reduced tube voltage (100 vs 120 kV) (univariate: -6.4 mSv [-7.4 to -5.4]), and use of automatic exposure control (univariate: -5.3 mSv [-6.2 to -4.4]). CONCLUSIONS: CCTA radiation doses were reduced 74.8% through increasing use of dose-saving measures and evolving scanner technology.
PURPOSE: We aimed to assess the temporal change in radiation doses from coronary computed tomography angiography (CCTA) during a 6-year period. High CCTA radiation doses have been reduced by multiple technologies that, if used appropriately, can decrease exposures significantly. METHODS: A total of 1277 examinations performed from 2005 to 2010 were included. Univariate and multivariable regression analysis of patient- and scan-related variables was performed with estimated radiation dose as the main outcome measure. RESULTS: Median doses decreased by 74.8% (P<.001), from 13.1 millisieverts (mSv) (interquartile range 9.3-14.7) in period 1 to 3.3 mSv (1.8-6.7) in period 4. Factors associated with greatest dose reductions (P<.001) were all most frequently applied in period 4: axial-sequential acquisition (univariate: -8.0 mSv [-9.7 to -7.9]), high-pitch helical acquisition (univariate: -8.8 mSv [-9.3 to -7.9]), reduced tube voltage (100 vs 120 kV) (univariate: -6.4 mSv [-7.4 to -5.4]), and use of automatic exposure control (univariate: -5.3 mSv [-6.2 to -4.4]). CONCLUSIONS:CCTA radiation doses were reduced 74.8% through increasing use of dose-saving measures and evolving scanner technology.
Authors: Salvatore Carbonaro; Todd C Villines; Jörg Hausleiter; Patrick J Devine; Thomas C Gerber; Allen J Taylor Journal: J Cardiovasc Comput Tomogr Date: 2009-05-27
Authors: Gilbert L Raff; Kavitha M Chinnaiyan; David A Share; Tauqir Y Goraya; Ella A Kazerooni; Mauro Moscucci; Ralph E Gentry; Aiden Abidov Journal: JAMA Date: 2009-06-10 Impact factor: 56.272
Authors: Jörg Hausleiter; Tanja Meyer; Franziska Hermann; Martin Hadamitzky; Markus Krebs; Thomas C Gerber; Cynthia McCollough; Stefan Martinoff; Adnan Kastrati; Albert Schömig; Stephan Achenbach Journal: JAMA Date: 2009-02-04 Impact factor: 56.272
Authors: Eduardo M Vilela; Catarina Ruivo; Claudio E Guerreiro; Marisa P Silva; Ricardo Ladeiras-Lopes; Daniel Caeiro; Gustavo P Morais; João Primo; Pedro Braga; Nuno Ferreira; José Pedro L Nunes; Vasco Gama Ribeiro Journal: Ther Adv Cardiovasc Dis Date: 2018-08-15
Authors: Ashley M Lee; Jonathan Beaudoin; Leif-Christopher Engel; Manavjot S Sidhu; Suhny Abbara; Thomas J Brady; Udo Hoffmann; Brian B Ghoshhajra Journal: Int J Cardiovasc Imaging Date: 2013-03-24 Impact factor: 2.357
Authors: A Pursnani; A Lee; T Mayrhofer; M Panagia; U Sharma; S Abbara; U Hoffmann; B B Ghoshhajra Journal: Br J Radiol Date: 2014-06-02 Impact factor: 3.039
Authors: Edward Hulten; Marcio Sommer Bittencourt; Brian Ghoshhajra; Daniel O'Leary; Mitalee P Christman; Michael J Blaha; Quynh Truong; Kyle Nelson; Philip Montana; Michael Steigner; Frank Rybicki; Jon Hainer; Thomas J Brady; Udo Hoffmann; Marcelo F Di Carli; Khurram Nasir; Suhny Abbara; Ron Blankstein Journal: Atherosclerosis Date: 2014-01-08 Impact factor: 5.162