Literature DB >> 11487830

Effective dose to a patient undergoing coronary angiography.

H Lobotessi1, A Karoussou, V Neofotistou, A Louisi, V Tsapaki.   

Abstract

Detailed data relating to patient dose have been acquired for 18, randomly chosen, patients undergoing coronary angiographies. During the procedure, dose-area product (DAP), kV and beam collimation were recorded for each projection. Total DAP, fluoroscopy time and number of cine frames were also noted. Patient effective doses were calculated using two different methods. Mean and median DAP values were 58 and 56 Gy.cm2 respectively, with a range between 26 and 125 Gy.cm2, screening time ranged from 3 to 37 min and cine frames from 1013 to 2344, depending on patient size, examination protocol and complexity of procedure. Our results correspond well with those obtained by other authors. Differences in the estimation of effective doses, due to the calculation method used and the approximation made, are discussed.

Entities:  

Mesh:

Year:  2001        PMID: 11487830     DOI: 10.1093/oxfordjournals.rpd.a006466

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  13 in total

Review 1.  Advances in cardiovascular CT imaging: CT technology.

Authors:  Bryan R Westerman
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

2.  Radiation exposure benefit of a lead cap in invasive cardiology.

Authors:  E Kuon; J Birkel; M Schmitt; J B Dahm
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

3.  Radiation-reducing planning of cardiac catheterisation.

Authors:  E Kuon; J B Dahm; D M Robinson; K Empen; M Günther; W Wucherer
Journal:  Z Kardiol       Date:  2005-10

4.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

5.  Diagnostic accuracy of 320-row computed tomography as compared with invasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease.

Authors:  F Pelliccia; V Pasceri; A Evangelista; A Pergolini; F Barillà; N Viceconte; G Tanzilli; M Schiariti; C Greco; C Gaudio
Journal:  Int J Cardiovasc Imaging       Date:  2012-07-18       Impact factor: 2.357

6.  Non-invasive assessment of coronary artery disease with CT coronary angiography and SPECT: a novel dose-saving fast-track algorithm.

Authors:  Aju P Pazhenkottil; Bernhard A Herzog; Lars Husmann; Ronny R Buechel; Irene A Burger; Ines Valenta; Ulf Landmesser; Christophe A Wyss; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-30       Impact factor: 9.236

7.  Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography.

Authors:  Anja Deetjen; Susanne Möllmann; Guido Conradi; Andreas Rolf; Axel Schmermund; Christian W Hamm; Thorsten Dill
Journal:  Heart       Date:  2007-03-29       Impact factor: 5.994

8.  Preliminary reference levels in interventional cardiology.

Authors:  V Neofotistou; E Vano; R Padovani; J Kotre; A Dowling; M Toivonen; S Kottou; V Tsapaki; S Willis; G Bernardi; K Faulkner
Journal:  Eur Radiol       Date:  2003-02-20       Impact factor: 5.315

9.  Evaluation of patient-absorbed doses during coronary angiography and intervention by femoral and radial artery access.

Authors:  Michael Sandborg; Sven-Göran Fransson; Håkan Pettersson
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

10.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.