Chest CT performed with z-axis modulation: scanning protocol and radiation dose.

Mannudeep K Kalra1, Stefania Rizzo, Michael M Maher, Elkan F Halpern, Thomas L Toth, Jo-Anne O Shepard, Suzanne L Aquino.   

Abstract

Institutional review board approval of the study protocol and waiver of informed consent were obtained. This study was compliant with the Health Insurance Portability and Accountability Act. The purpose of this study was to retrospectively assess the scanning protocol and radiation dose associated with z-axis automatic tube current modulation in multi-detector row CT scanning of the chest. Fifty-three patients (mean age, 54 years; age range, 26-77 years; 25 men, 28 women) underwent 16-detector row chest CT with z-axis modulation and noise indexes of 10.0, 12.5, and 15.0 HU. Two radiologists independently compared images acquired with z-axis modulation and fixed tube current (180-300 mA) techniques for image noise, diagnostic acceptability, and depiction of peripheral bronchovascular markings. Tube current-time product was calculated for each study. There was good interobserver agreement between the two readers (kappa = 0.72). Compared with the fixed tube current technique, z-axis modulation provides acceptable image noise for chest CT, with an 18% and 26% reduction in tube current-time product at 10.0- and 12.5-HU noise indexes, respectively. RSNA, 2005

Entities:  

Mesh:

Year:  2005        PMID: 16183938     DOI: 10.1148/radiol.2371041227

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  32 in total

1.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Low-dose CT screening for lung cancer with automatic exposure control: phantom study.

Authors:  Shiho Gomi; Yoshihisa Muramatsu; Shinsuke Tsukagoshi; Masahiro Suzuki; Ryutaro Kakinuma; Ryosuke Tsuchiya; Noriyuki Moriyama
Journal:  Radiol Phys Technol       Date:  2008-07-11

3.  The influences of tube voltage and scan direction on combined tube current modulation: a phantom study.

Authors:  Hyun Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-04-27

4.  Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose.

Authors:  S Namasivayam; M K Kalra; K M Pottala; S M Waldrop; P A Hudgins
Journal:  AJNR Am J Neuroradiol       Date:  2006 Nov-Dec       Impact factor: 3.825

Review 5.  Radiation dose-reduction strategies for neuroradiology CT protocols.

Authors:  A B Smith; W P Dillon; R Gould; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

6.  Dose of reduced z-axis length of computed tomography angiography (CTA) of the chest for pulmonary embolism using 64-detector rows and adaptive iterative reconstruction techniques.

Authors:  Jared Martillotti; Naomi Silva; Jyoti Chhabra; Christian Molstrom; Ryan Coughlin; Michael O'Loughlin; Bret Coughlin
Journal:  Emerg Radiol       Date:  2012-08-17

7.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

8.  64-Slice CT urography: optimisation of radiation dose.

Authors:  P Martingano; F Stacul; M F Cavallaro; S Cernic; P Bregant; M A Cova
Journal:  Radiol Med       Date:  2011-01-12       Impact factor: 3.469

9.  Determination of a standard deviation that could minimize radiation exposure in an automatic exposure control for pulmonary thin-section computed tomography.

Authors:  Atsushi Nambu; Eiichi Sawada; Satoshi Kato; Tsutomu Araki; Yoshihito Aikawa; Makoto Yuge; Akitoshi Saito
Journal:  Jpn J Radiol       Date:  2011-07-24       Impact factor: 2.374

10.  Is weight-based adjustment of automatic exposure control necessary for the reduction of chest CT radiation dose?

Authors:  Priyanka Prakash; Mannudeep K Kalra; Matthew D Gilman; Jo-Anne O Shepard; Subba R Digumarthy
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.