Literature DB >> 17221262

Acetabular revisions using a cementless oblong cup: five to ten year results.

R Civinini1, A Capone, C Carulli, M Villano, M I Gusso.   

Abstract

The purpose of this paper was to evaluate the results of acetabular revisions with the use of an oblong revision cup that is designed with its longitudinal diameter elongated relative to its transverse diameter. Between 1996 and 2001, 62 hips in 60 patients underwent an acetabular revision with the insertion of a LOR acetabular component. Seven hips were lost to follow-up or the patients died; the remaining 55 hips (53 patients) remained in follow-up for an average of 7.2 years (range: 5.0-10.1 years). One socket was revised for aseptic loosening, and another was operated on for a late polyethylene liner dissociation. The average Harris hip score (HHS) improved from 34 to 79. Results were rated as excellent in 16 hips, good in 28, fair in six and poor in three. Radiographic analysis demonstrated an improvement in the average vertical displacement of the hip centre: 49 hips had a well-fixed, bone-ingrown cup and four had a stable fibrous union. For large superolateral acetabular bone deficiencies, this implant facilitated a complex reconstruction without the need for bulk structural acetabular bone grafts, provided good clinical results and showed satisfactory stability at the midterm follow-up.

Entities:  

Mesh:

Year:  2007        PMID: 17221262      PMCID: PMC2269016          DOI: 10.1007/s00264-006-0307-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  21 in total

1.  Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study.

Authors:  J T Dearborn; W H Harris
Journal:  J Arthroplasty       Date:  2000-01       Impact factor: 4.757

2.  Cementless acetabular revision for aseptic failure of cemented hip arthroplasty.

Authors:  K Chareancholvanich; A Tanchuling; T Seki; R B Gustilo
Journal:  Clin Orthop Relat Res       Date:  1999-04       Impact factor: 4.176

3.  Acetabular revision surgery with the LOR cup: three to 8 years' follow-up.

Authors:  Michele F Surace; Giovanni Zatti; Marco De Pietri; Paolo Cherubino
Journal:  J Arthroplasty       Date:  2006-01       Impact factor: 4.757

4.  Management of types III and IV acetabular deficiencies with the longitudinal oblong revision cup.

Authors:  Antonio Herrera; Angel Antonio Martínez; Jorge Cuenca; Vicente Canales
Journal:  J Arthroplasty       Date:  2006-09       Impact factor: 4.757

5.  Reconstruction of the deficient acetabulum with an oblong prosthesis: three- to seven-year results.

Authors:  D K DeBoer; M J Christie
Journal:  J Arthroplasty       Date:  1998-09       Impact factor: 4.757

6.  Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency.

Authors:  W M Chen; C A Engh; R H Hopper; J P McAuley; C A Engh
Journal:  J Bone Joint Surg Am       Date:  2000-02       Impact factor: 5.284

7.  Cementless acetabular revision. Evaluation at an average of 10.5 years.

Authors:  S S Leopold; A G Rosenberg; R D Bhatt; M B Sheinkop; L R Quigley; J O Galante
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

8.  Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty.

Authors:  A L Whaley; D J Berry; W S Harmsen
Journal:  J Bone Joint Surg Am       Date:  2001-09       Impact factor: 5.284

9.  Acetabular revision using a trabecular metal acetabular component for severe acetabular bone loss associated with a pelvic discontinuity.

Authors:  Scott M Sporer; Wayne G Paprosky
Journal:  J Arthroplasty       Date:  2006-09       Impact factor: 4.757

10.  Bilobed oblong porous coated acetabular components in revision total hip arthroplasty.

Authors:  D J Berry; C J Sutherland; R T Trousdale; C W Colwell; H P Chandler; D Ayres; A A Yashar
Journal:  Clin Orthop Relat Res       Date:  2000-02       Impact factor: 4.176

View more
  11 in total

1.  Clinical and radiographic assessment of cementless acetabular revision with morsellised allografts.

Authors:  Chuang Sun; Yong-Yun Lian; Yu-Hua Jin; Cheng-Bin Zhao; Shi-Qi Pan; Xue-Feng Liu
Journal:  Int Orthop       Date:  2009-02-26       Impact factor: 3.075

Review 2.  [Comparison of different cup revision systems].

Authors:  K Trieb
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 3.  Cementless acetabular revision: past, present, and future. Revision total hip arthroplasty: the acetabular side using cementless implants.

Authors:  Luis Pulido; Sridhar R Rachala; Miguel E Cabanela
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

4.  [Treatment of acetabular bone defects in revision hip arthroplasty using the Revisio-System].

Authors:  M Hoberg; B M Holzapfel; A F Steinert; F Kratzer; M Walcher; M Rudert
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

5.  [Standardized reconstruction of acetabular bone defects using the cranial socket system].

Authors:  Maximilian Rudert; Boris Michael Holzapfel; Florian Kratzer; Reiner Gradinger
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

6.  Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trč-Cingr cup.

Authors:  Eduard Šťastný; Tomáš Trč; Milan Handl; Petr Kos; Jakub Kautzner; Theodoros Philippou; Jiří Lisý
Journal:  Int Orthop       Date:  2014-01-16       Impact factor: 3.075

7.  Trabecular titanium cups in acetabular revision arthroplasty: analysis of 10-year survivorship, restoration of center of rotation and osteointegration.

Authors:  Andrea Cozzi Lepri; Matteo Innocenti; Alberto Galeotti; Christian Carulli; Marco Villano; Roberto Civinini
Journal:  Arch Orthop Trauma Surg       Date:  2021-11-15       Impact factor: 2.928

8.  [Acetabular revision surgery with the oblong revision cup : clinical and radiological results of 217 cases].

Authors:  S Fickert; S Pfeiffer; A Walter; K P Günther; W-C Witzleb
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

9.  Satisfying outcomes scores and survivorship achieved with impaction grafting for revision THA in young patients.

Authors:  Martijn A J Te Stroet; Wim H C Rijnen; Jean W M Gardeniers; Albert van Kampen; B Willem Schreurs
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

10.  Protrusion of a ceramic femoral head through the acetabular metallic cup in total-hip arthroplasty: A case report.

Authors:  Ding Zhao; De-Bao Zhang; Dong-Feng Han; Gui-Shan Gu
Journal:  Medicine (Baltimore)       Date:  2020-06-12       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.