Literature DB >> 24430429

Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trč-Cingr cup.

Eduard Šťastný1, Tomáš Trč, Milan Handl, Petr Kos, Jakub Kautzner, Theodoros Philippou, Jiří Lisý.   

Abstract

PURPOSE: The aim of the present study was to introduce a novel oblong revision cup type TC for use in revision total hip arthroplasty (THA), and to evaluate mid-term results in terms of bone tissue remodelling in the immediate area of the implant.
METHODS: The results of 31 patients that underwent revision THA between 2004 and 2008 are presented. The mean follow-up interval was 7.1 years (range 5.3-9.3 years, minimum of five years following revision). Osteointegration of the implant and bone tissue remodelling around the implant and ribs were assessed by X-ray and computed tomography (CT).
RESULTS: The average Harris hip score increased from 39.8 to 85.3. Excellent results were achieved in nine patients, good in 16, fair in three and poor in three. According to X-ray results, 25 hips had a well-fixed, bone-ingrown cup and five had a stable fibrous union in the middle and the distal third of the implant. Proximal migration of the cup was noted in one case. Pelvic CT was additionally performed in ten patients. In all cases, we detected bone remodelling in the space between the implant ribs. Kaplan-Maier survivorship of the acetabular components was 94.2 % at 7.1 years.
CONCLUSIONS: Our results show that the novel oblong revision cup type TC is relatively simple to implant, and is associated with reliable primary fixation and documented osteointegration and bone remodelling in the immediate area.

Entities:  

Mesh:

Year:  2014        PMID: 24430429      PMCID: PMC3997770          DOI: 10.1007/s00264-013-2269-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  20 in total

1.  [Total hip joint replacement with the Walter type of prosthesis--long-term results].

Authors:  I Landor; P Vavrík; A Sosna; J Bek
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2001       Impact factor: 0.531

2.  Use of oblong socket in hip revision surgery.

Authors:  H U Cameron; V Smula
Journal:  Acta Chir Orthop Traumatol Cech       Date:  1999       Impact factor: 0.531

3.  Revision of a failed cemented total hip prosthesis with insertion of an acetabular component without cement and a femoral component with cement. A five to eight-year follow-up study.

Authors:  K L Weber; J J Callaghan; D D Goetz; R C Johnston
Journal:  J Bone Joint Surg Am       Date:  1996-07       Impact factor: 5.284

4.  Acetabular revisions using a cementless oblong cup: five to ten year results.

Authors:  R Civinini; A Capone; C Carulli; M Villano; M I Gusso
Journal:  Int Orthop       Date:  2007-01-13       Impact factor: 3.075

5.  Oblong cup in the management of aseptic loosening of the acetabular component in total hip replacement.

Authors:  J Fousek; P Vasek
Journal:  Scand J Surg       Date:  2007       Impact factor: 2.360

6.  Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography.

Authors:  Buster Sandgren; Joakim Crafoord; Göran Garellick; Lars Carlsson; Lars Weidenhielm; Henrik Olivecrona
Journal:  J Arthroplasty       Date:  2013-04-22       Impact factor: 4.757

7.  Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency.

Authors:  W M Chen; C A Engh; R H Hopper; J P McAuley; C A Engh
Journal:  J Bone Joint Surg Am       Date:  2000-02       Impact factor: 5.284

8.  An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up.

Authors:  G Köster; H G Willert; H P Köhler; K Döpkens
Journal:  J Arthroplasty       Date:  1998-08       Impact factor: 4.757

9.  Multislice computed tomography for evaluating acetabular defects in revision THA.

Authors:  Eduardo Garcia-Cimbrelo; Mar Tapia; Carmen Martin-Hervas
Journal:  Clin Orthop Relat Res       Date:  2007-10       Impact factor: 4.176

10.  [Oblong implants for revision total hip arthroplasty].

Authors:  I Landor; P Vavrík; D Jahoda; D Pokorný; S Popelka; A Sosna
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2009-12       Impact factor: 0.531

View more
  1 in total

1.  Acetabular revision arthroplasty using trabecular titanium implants.

Authors:  Boris Steno; Milan Kokavec; Libor Necas
Journal:  Int Orthop       Date:  2014-09-06       Impact factor: 3.075

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.