Literature DB >> 19242693

Clinical and radiographic assessment of cementless acetabular revision with morsellised allografts.

Chuang Sun1, Yong-Yun Lian, Yu-Hua Jin, Cheng-Bin Zhao, Shi-Qi Pan, Xue-Feng Liu.   

Abstract

The aim of this study was to evaluate the clinical and radiographic results of cementless acetabular revision with deep frozen morsellised allografts. Sixty-one patients (65 hips) underwent acetabular revision using cementless components and deep frozen morsellised allografts. Fifty-seven hips (53 patients) were reviewed at a mean of 105.1 months (range 72-180 months) after revision. The study group included 29 males and 24 females with a mean age of 46.4 years. One cup underwent further revision for aseptic loosening and two were defined as radiographic failures. The mean time for allograft incorporation was 12.5 months (range 6-24 months) after index surgery. The mean Harris hip score of the patients improved from 61.1 points preoperatively to 91.6 points postoperatively. Linear and cavitary osteolysis was observed in two and 12 hips, respectively. The acetabular revision using cementless components with deep frozen morsellized allografts provides favourable clinical and radiographic results, although the initial disease and age may adversely affect the outcomes.

Entities:  

Mesh:

Year:  2009        PMID: 19242693      PMCID: PMC2899160          DOI: 10.1007/s00264-009-0722-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  23 in total

1.  Techniques to improve the shear strength of impacted bone graft: the effect of particle size and washing of the graft.

Authors:  Douglas G Dunlop; Nigel T Brewster; S P Gopal Madabhushi; Asif S Usmani; P Pankaj; Colin R Howie
Journal:  J Bone Joint Surg Am       Date:  2003-04       Impact factor: 5.284

2.  Rapid bone and blood flow formation in impacted morselized allografts: positron emission tomography (PET) studies on allografts in 5 femoral component revisions of total hip arthroplasty.

Authors:  Jens Sörensen; Gösta Ullmark; Bengt Långström; Olle Nilsson
Journal:  Acta Orthop Scand       Date:  2003-12

3.  Larger bone graft size and washing of bone grafts prior to impaction enhances the initial stability of cemented cups: experiments using a synthetic acetabular model.

Authors:  J J Chris Arts; Nico Verdonschot; Pieter Buma; B Willem Schreurs
Journal:  Acta Orthop       Date:  2006-04       Impact factor: 3.717

4.  Type III acetabular defect revision with bilobed components: five-year results.

Authors:  Joseph T Moskal; Michael E Higgins; Joseph Shen
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

5.  Results of revision of hip arthroplasty with cement. A five to fourteen-year follow-up study.

Authors:  R K Marti; H M Schüller; P P Besselaar; E L Vanfrank Haasnoot
Journal:  J Bone Joint Surg Am       Date:  1990-03       Impact factor: 5.284

6.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

7.  The incorporation of morselized bone grafts in cementless acetabular revisions.

Authors:  Gracia Etienne; Hari P Bezwada; David S Hungerford; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

8.  Rinsing morselized allografts improves bone and tissue ingrowth.

Authors:  Sanne van der Donk; Tim Weernink; Pieter Buma; Per Aspenberg; Tom J J H Slooff; B Willem Schreurs
Journal:  Clin Orthop Relat Res       Date:  2003-03       Impact factor: 4.176

9.  Acetabular revision arthroplasty using jumbo cups: an experience in Asia.

Authors:  Cheng-Yu Fan; Wei-Ming Chen; Ocar K Lee; Ching-Kuei Huang; Chao-Ching Chiang; Tain-Hsiung Chen
Journal:  Arch Orthop Trauma Surg       Date:  2007-11-06       Impact factor: 3.067

10.  Classification and management of acetabular abnormalities in total hip arthroplasty.

Authors:  J A D'Antonio; W N Capello; L S Borden; W L Bargar; B F Bierbaum; W G Boettcher; M E Steinberg; S D Stulberg; J H Wedge
Journal:  Clin Orthop Relat Res       Date:  1989-06       Impact factor: 4.176

View more
  3 in total

1.  The use of fibre-based demineralised bone matrix in major acetabular reconstruction: surgical technique and preliminary results.

Authors:  Moussa Hamadouche; Mathieu Karoubi; Valérie Dumaine; Jean Pierre Courpied
Journal:  Int Orthop       Date:  2010-11-06       Impact factor: 3.075

2.  The use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4- to 9-year follow-up.

Authors:  Huifeng Ding; Yuanqing Mao; Bin Yu; Zhenan Zhu; Huiwu Li; Baoqing Yu; Jianming Huang
Journal:  J Orthop Surg Res       Date:  2015-05-23       Impact factor: 2.359

Review 3.  Acetabular Cup Revision Arthroplasty Using Morselized Impaction Allograft.

Authors:  Joong-Myung Lee; Tae-Ho Kim
Journal:  Hip Pelvis       Date:  2018-06-04
  3 in total