Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9-2.4), while smooth kernel provided only acceptable/poor image quality (3.9-4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (> or =50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature.

Entities:  

Mesh:

Year:  2006        PMID: 16733677     DOI: 10.1007/s00330-006-0315-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  37 in total

1.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

2.  Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting.

Authors:  X Leclerc; J Y Gauvrit; J P Pruvo
Journal:  AJR Am J Roentgenol       Date:  2000-03       Impact factor: 3.959

3.  Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents.

Authors:  M Lenhart; M Völk; C Manke; W R Nitz; M Strotzer; S Feuerbach; J Link
Journal:  Radiology       Date:  2000-10       Impact factor: 11.105

Review 4.  Use of high concentration contrast media: principles and rationale-vascular district.

Authors:  Dominik Fleischmann
Journal:  Eur J Radiol       Date:  2003-03       Impact factor: 3.528

5.  Aortoiliac and lower extremity arteries: comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography.

Authors:  E Sueyoshi; I Sakamoto; Y Matsuoka; Y Ogawa; H Hayashi; R Hashmi; K Hayashi
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

6.  Sonographic follow-up after visceral artery stenting.

Authors:  Zita Morvay; Endre Nagy; Róbert Bagi; Gyorgy Abrahám; Róbert Sipka; András Palkó
Journal:  J Ultrasound Med       Date:  2004-08       Impact factor: 2.153

7.  Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

Authors:  Harald Seifarth; Rainer Raupach; Stefan Schaller; Eva Maria Fallenberg; Thomas Flohr; Walter Heindel; Roman Fischbach; David Maintz
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

8.  Iliofemoral arterial occlusive disease: contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement.

Authors:  J Link; J C Steffens; J Brossmann; J Graessner; S Hackethal; M Heller
Journal:  Radiology       Date:  1999-08       Impact factor: 11.105

9.  Peripheral artery stent visualization and in-stent stenosis analysis in 16-row computed tomography: an in-vitro evaluation.

Authors:  Christopher Herzog; Christine Grebe; Andreas Mahnken; Joern O Balzer; Martin G Mack; Stefan Zangos; Hanns Ackermann; Stefan Schaller; Tobias Seifert; Bernd Ohnesorge; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-07-14       Impact factor: 5.315

10.  Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease.

Authors:  Christoph U Herborn; Mathias Goyen; Harald H Quick; Silke Bosk; Sandra Massing; Knut Kroeger; Dirk Stoesser; Stefan G Ruehm; Jörg F Debatin
Journal:  AJR Am J Roentgenol       Date:  2004-06       Impact factor: 3.959

View more
  5 in total

1.  Carotid artery stents: in vitro comparison of different stent designs and sizes using CT angiography and contrast-enhanced MR angiography at 1.5T and 3T.

Authors:  M Lettau; A Sauer; S Heiland; S Rohde; M Bendszus; S Hähnel
Journal:  AJNR Am J Neuroradiol       Date:  2009-09-12       Impact factor: 3.825

2.  Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

Authors:  Michael Lettau; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2013-02-15       Impact factor: 2.804

Review 3.  [Chronic critical ischemia of the lower leg: pretherapeutic imaging and methods for revascularization].

Authors:  M Treitl; V Ruppert; A K Mayer; C Degenhart; M Reiser; J Rieger
Journal:  Radiologe       Date:  2006-11       Impact factor: 0.635

4.  In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T.

Authors:  Michael Lettau; Annett Sauer; Sabine Heiland; Stefan Rohde; Julia Reinhardt; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2009-11-19       Impact factor: 2.804

5.  Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types.

Authors:  Michael Köhler; Matthias C Burg; Alexander C Bunck; Walter Heindel; Harald Seifarth; David Maintz
Journal:  Radiol Res Pract       Date:  2011-07-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.