Literature DB >> 12598032

Use of high concentration contrast media: principles and rationale-vascular district.

Dominik Fleischmann1.   

Abstract

Optimal contrast medium delivery remains a crucial issue in CT angiography and it will become even more critical with continuously evolving, faster CT scanner technology. This review article first explains the fundamentals of arterial enhancement using mathematical models of early contrast medium dynamics. The relationship of contrast medium volume, injection flow rates and injection duration are explicitly illustrated. Next, current techniques of contrast medium application are reviewed, with particular attention to methods of accurate timing of the scanning delay (test-bolus and automated bolus triggering), tools for automated saline-flushing of the veins (double-syringe power injectors) and the use of high-concentration contrast medium. From there, rational CT angiographic injection protocols for a wide range of selectable acquisition times for 4-, 8- and 16-channel MDCT are proposed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12598032     DOI: 10.1016/s0720-048x(02)00365-0

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  26 in total

Review 1.  Cardiac and vascular MDCT: thoracic imaging.

Authors:  Andreas F Kopp; Axel Küttner; Tobias Trabold; Martin Heuschmid; Stephen Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 2.  Optimizing technique for multi-slice CT.

Authors:  Sanjay Saini; Roy V Dsouza
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  [CTA of carotid artery with different scanner types].

Authors:  M Lell; K Anders; C Leidecker; W Lang; W Bautz; M Uder
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

4.  Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

Authors:  Marja Berg; Zishu Zhang; Aki Ikonen; Petri Sipola; Reetta Kälviäinen; Hannu Manninen; Ritva Vanninen
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

5.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

6.  Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography.

Authors:  Takeshi Nakaura; Kazuo Awai; Yumi Yanaga; Tomohiro Namimoto; Daisuke Utsunomiya; Toshinori Hirai; Seigo Sugiyama; Hisao Ogawa; Masahito Aoyama; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2011-09-01       Impact factor: 2.374

7.  Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT.

Authors:  Florian F Behrendt; Hubertus Pietsch; Gregor Jost; Martin A Sieber; Sebastian Keil; Cedric Plumhans; Peter Seidensticker; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2010-02-24       Impact factor: 5.315

8.  Improved aortic enhancement in CT angiography using slope-based triggering with table speed optimization: a pilot study.

Authors:  Mustafa R Bashir; Paul W Weber; Daniela B Husarik; Laurens E Howle; Rendon C Nelson
Journal:  Int J Cardiovasc Imaging       Date:  2011-09-07       Impact factor: 2.357

9.  Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose.

Authors:  Annemarieke Rutten; Matthijs F L Meijs; Alexander M de Vos; Peter R Seidensticker; Mathias Prokop
Journal:  Eur Radiol       Date:  2010-03-20       Impact factor: 5.315

10.  Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: a comparison of the use of iopromide 370 and iomeprol 400.

Authors:  Eun Young Kim; Dae Wook Yeh; Yeon Hyeon Choe; Won Jae Lee; Hyo Keun Lim
Journal:  Acta Radiol       Date:  2010-11       Impact factor: 1.990

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.