Literature DB >> 16021457

Peripheral artery stent visualization and in-stent stenosis analysis in 16-row computed tomography: an in-vitro evaluation.

Christopher Herzog1, Christine Grebe, Andreas Mahnken, Joern O Balzer, Martin G Mack, Stefan Zangos, Hanns Ackermann, Stefan Schaller, Tobias Seifert, Bernd Ohnesorge, Thomas J Vogl.   

Abstract

The accuracy of 16-row multidetector CT in the visualization of different peripheral artery stents and in the appraisal of in-stent stenosis was assessed. Nine different stent types (nitinol and stainless steel) with three diameters (6, 8 and 10 mm) were used; altogether 27 stents were analyzed in a barrel-shaped vascular model. Low-grade (<40%) and high-grade (>60%) in-stent stenoses were simulated by polyurethane sticks (70 HU) of differing diameters (2-6 mm). Imaging was performed with 16x0.75-mm detector collimation, 130 mAs, 120 kV, 12-mm table feed/rotation, 1.0-mm slice thickness and 0.5-mm increment. The stent diameter, strut thickness, in-stent attenuation values, degree and degree of in-stent stenosis were evaluated. Nitinol stents showed significantly (P<10-6) less stent lumen narrowing, artificial strut thickening and overestimation of the degree of in-stent stenoses than stainless steel stents. In-stent attenuation values and artificial strut thickening were significantly (P<10-6) lower in 10- and 8-mm stents than in 6-mm stents. Stent lumen narrowing was significantly less in 10-mm stents than in 8-mm (P<10-4) or 6-mm (P<10-6) stents. In-stent stenoses were significantly overestimated, irrespective of the stent diameter. In 6-mm stents overestimation was significantly higher than in 8-mm (P<0.01) or 10-mm stents (P<10-6). Under in-vitro conditions 16-row MDCT allowed an accurate identification of in-stent stenosis, but significantly overestimated the effective degree of the stenosis.

Entities:  

Mesh:

Year:  2005        PMID: 16021457     DOI: 10.1007/s00330-005-2797-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  Appearance of vascular stents in computed tomographic angiography: in vitro examination of 14 different stent types.

Authors:  M Strotzer; M Lenhart; B Butz; M Völk; C Manke; S Feuerbach
Journal:  Invest Radiol       Date:  2001-11       Impact factor: 6.016

2.  Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation.

Authors:  David Maintz; Kai-Uwe Juergens; Thomas Wichter; Matthias Grude; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2002-09-07       Impact factor: 5.315

3.  Multidetector CT angiography of peripheral vascular disease: a prospective comparison with intraarterial digital subtraction angiography.

Authors:  Amos Ofer; Samy S Nitecki; Shai Linn; Monica Epelman; Doron Fischer; Tony Karram; Diana Litmanovich; Henry Schwartz; Aaron Hoffman; Ahuva Engel
Journal:  AJR Am J Roentgenol       Date:  2003-03       Impact factor: 3.959

4.  Revealing in-stent stenoses of the iliac arteries: comparison of multidetector CT with MR angiography and digital radiographic angiography in a Phantom model.

Authors:  David Maintz; Bernd Tombach; Kai-Uwe Juergens; Stefanie Weigel; Walter Heindel; Roman Fischbach
Journal:  AJR Am J Roentgenol       Date:  2002-11       Impact factor: 3.959

Review 5.  Multidetector row computed tomography of the aorta and peripheral arteries.

Authors:  Leo P Lawler; Elliot K Fishman
Journal:  Cardiol Clin       Date:  2003-11       Impact factor: 2.213

6.  MDCT compared with digital subtraction angiography for assessment of lower extremity arterial occlusive disease: importance of reviewing cross-sectional images.

Authors:  Hideki Ota; Kei Takase; Kazumasa Igarashi; Yoshihiro Chiba; Kenichi Haga; Haruo Saito; Shoki Takahashi
Journal:  AJR Am J Roentgenol       Date:  2004-01       Impact factor: 3.959

7.  Coronary artery stents in multislice computed tomography: in vitro artifact evaluation.

Authors:  Andreas H Mahnken; Arno Buecker; Joachim E Wildberger; Alexander Ruebben; Sven Stanzel; Felix Vogt; Rolf W Günther; Rüdiger Blindt
Journal:  Invest Radiol       Date:  2004-01       Impact factor: 6.016

8.  Small vessel stents for intracranial angioplasty: in vitro evaluation of in-stent stenoses using CT angiography.

Authors:  M Trossbach; M Hartmann; C Braun; K Sartor; S Hähnel
Journal:  Neuroradiology       Date:  2004-05-01       Impact factor: 2.804

9.  [Current status and future potentials of multislice computed tomography].

Authors:  T Flohr; B Ohnesorge; S Schaller
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

10.  Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility.

Authors:  D Maintz; R Fischbach; K U Juergens; T Allkemper; J Wessling; W Heindel
Journal:  Invest Radiol       Date:  2001-12       Impact factor: 6.016

View more
  5 in total

Review 1.  Superficial femoral artery: current treatment options.

Authors:  Gunnar Tepe; Jörg Schmehl; Stephan Heller; Benjamin Wiesinger; Claus D Claussen; Stephan H Duda
Journal:  Eur Radiol       Date:  2006-02-18       Impact factor: 5.315

2.  Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings.

Authors:  Martin Heuschmid; Benjamin Wiesinger; Gunnar Tepe; Oliver Luz; Andreas F Kopp; Claus D Claussen; Stephan H Duda
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

3.  Accuracy of multislice CT angiography for the assessment of in-stent restenoses in the iliac arteries at reduced dose: a phantom study.

Authors:  K Perisinakis; E Manousaki; K Zourari; D Tsetis; A Tzedakis; A Papadakis; A Karantanas; J Damilakis
Journal:  Br J Radiol       Date:  2011-03       Impact factor: 3.039

4.  Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types.

Authors:  Michael Köhler; Matthias C Burg; Alexander C Bunck; Walter Heindel; Harald Seifarth; David Maintz
Journal:  Radiol Res Pract       Date:  2011-07-18

5.  MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types.

Authors:  Matthias C Burg; Alexander C Bunck; Harald Seifarth; Boris Buerke; Harald Kugel; Volker Hesselmann; Michael Köhler; Walter Heindel; David Maintz
Journal:  Radiol Res Pract       Date:  2010-07-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.