Literature DB >> 10565510

Subsecond multi-slice computed tomography: basics and applications.

K Klingenbeck-Regn1, S Schaller, T Flohr, B Ohnesorge, A F Kopp, U Baum.   

Abstract

The recent advent of multislice-scanning is the first real quantum leap in computed tomography since the introduction of spiral CT in the early 90s. We discuss basic theoretical considerations important for the design of multislice scanners. Then, specific issues, like the design of the detector and spiral interpolation schemes are addressed briefly for the SOMATOM PLUS 4 Volume Zoom. The theoretical concepts are validated with phantom measurements. We finally show the large potential of the new technology for clinical applications. The concurrent acquisition of multiple slices results in a dramatic reduction of scan time for a given scan technique. This allows scanning volumes previously inaccessible. Similarly, given volumes can be scanned at narrower collimation, i.e. higher axial resolution in a given time. From data acquired at narrow collimation, both high-resolution studies and standard images can be reconstructed in the so-called Combi-Mode. This on the one hand reduces dose exposure to the patient because repeated scanning of a patient is no longer required. On the other hand, standard reconstructions benefit from narrow collimation as Partial Volume Artifacts are drastically suppressed. The rotational speed of 0.5 s of the SOMATOM PLUS 4 Volume Zoom furthermore opens up a whole range of new applications in cardiac CT. For the first time, virtually motion-free images can be acquired even for large volumes in a single breathhold by the combination of fast rotation and ECG triggering, respectively gating. We explain the underlying concepts and present initial results. The paper concludes with a brief discussion of the impact of the new technique on image display and postprocessing.

Entities:  

Mesh:

Year:  1999        PMID: 10565510     DOI: 10.1016/s0720-048x(99)00086-8

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  59 in total

1.  Effects of pretreatment with verapamil on early recurrences after electrical cardioversion of persistent atrial fibrillation: a randomised study.

Authors:  E Bertaglia; D D'Este; A Zanocco; F Zerbo; P Pascotto
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

2.  Acute pressure overload cardiac arrhythmias are dependent on the presence of myocardial tissue catecholamines.

Authors:  A J Drake-Holland; M I Noble; M J Lab
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

3.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

4.  Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study.

Authors:  G Brix; U Lechel; R Veit; R Truckenbrodt; G Stamm; E M Coppenrath; J Griebel; H-D Nagel
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

Review 5.  Optimizing technique for multi-slice CT.

Authors:  Sanjay Saini; Roy V Dsouza
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

6.  Preoperative imaging of chronic sinusitis by multislice computed tomography.

Authors:  Ingo Baumann; Assen Koitschev; Florian Dammann
Journal:  Eur Arch Otorhinolaryngol       Date:  2004-10       Impact factor: 2.503

7.  Contrast resolution in multidetector-row CT with 16 detector rows: phantom study.

Authors:  Kosuke Matsubara; Kichiro Koshida; Masayuki Suzuki; Norio Hayashi; Tadanori Takata; Hideo Tsujii; Tomoyuki Yamamoto; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2007-11-01

8.  Concept of minimal heart rate for each pitch value to avoid interpolation artifact when using dual-source CT: a phantom study.

Authors:  Joon-Won Kang; Kyung-Hyun Do; Jae-Yeon Chung; Hyun Jong Cho; Joon Beom Seo; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-30       Impact factor: 2.357

9.  3D-CT arteriography and 3D-CT venography: the separate demonstration of arterial-phase and venous-phase on 3D-CT angiography in a single procedure.

Authors:  Masato Matsumoto; Namio Kodama; Jun Sakuma; Sonomi Sato; Masahiro Oinuma; Yutaka Konno; Kyouichi Suzuki; Tatsuya Sasaki; Kenji Suzuki; Toshihiko Katakura; Fumio Shishido
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

10.  Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Authors:  Birgit B Ertl-Wagner; Roland Bruening; Jeffrey Blume; Ralf-Thorsten Hoffmann; Brad Snyder; Karin A Herrmann; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2005-03-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.