INTRODUCTION: CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. The purpose of this study was to compare CTA, contrast-enhanced MRA (CEMRA) at 1.5 T, and CEMRA at 3 T for the visualization of carotid artery stents and to define the best noninvasive imaging technique for each stent. METHODS: CTA and CEMRA appearances of 18 carotid artery stents of different designs and sizes (4.0 to 10.0 mm) were investigated in vitro. The profile of the contrast-to-noise ratio (CNR) of the lumen of each stent was calculated semiautomatically by a pixel-by-pixel analysis using the medical imaging software OSIRIS. For each stent, artificial lumen narrowing (ALN) was calculated. RESULTS: In all but one stents, ALN was lower on CEMRA at 3 T than at 1.5 T. With CEMRA at 3 T and at 1.5 T, ALN in most nitinol stents was lower than in the groups of stainless steel and cobalt alloy stents. In most nitinol stents, ALN on CEMRA at 3 T was lower than on CTA. In all stainless steel stents and cobalt alloy stents, ALN was lower on CTA than on CEMRA. With CTA and CEMRA, in most stents ALN decreased with increasing stent diameter. CONCLUSION: CTA and CEMRA evaluation of vessel patency after stent placement is possible, but considerably impaired by ALN. Investigators should be informed about the method of choice for every stent.
INTRODUCTION: CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. The purpose of this study was to compare CTA, contrast-enhanced MRA (CEMRA) at 1.5 T, and CEMRA at 3 T for the visualization of carotid artery stents and to define the best noninvasive imaging technique for each stent. METHODS: CTA and CEMRA appearances of 18 carotid artery stents of different designs and sizes (4.0 to 10.0 mm) were investigated in vitro. The profile of the contrast-to-noise ratio (CNR) of the lumen of each stent was calculated semiautomatically by a pixel-by-pixel analysis using the medical imaging software OSIRIS. For each stent, artificial lumen narrowing (ALN) was calculated. RESULTS: In all but one stents, ALN was lower on CEMRA at 3 T than at 1.5 T. With CEMRA at 3 T and at 1.5 T, ALN in most nitinol stents was lower than in the groups of stainless steel and cobalt alloy stents. In most nitinol stents, ALN on CEMRA at 3 T was lower than on CTA. In all stainless steel stents and cobalt alloy stents, ALN was lower on CTA than on CEMRA. With CTA and CEMRA, in most stents ALN decreased with increasing stent diameter. CONCLUSION: CTA and CEMRA evaluation of vessel patency after stent placement is possible, but considerably impaired by ALN. Investigators should be informed about the method of choice for every stent.
Authors: J M Meyer; A Buecker; E Spuentrup; K Schuermann; M Huetten; R D Hilgers; J J van Vaals; R W Guenther Journal: Invest Radiol Date: 2001-11 Impact factor: 6.016
Authors: Stefan C Krämer; Alexander Wall; David Maintz; Rainald Bachmann; Harald Kugel; Walter Heindel Journal: Invest Radiol Date: 2004-07 Impact factor: 6.016
Authors: Alexander Wall; Harald Kugel; Rainald Bachman; Lars Matuszewski; Stefan Krämer; Walter Heindel; David Maintz Journal: J Magn Reson Imaging Date: 2005-12 Impact factor: 4.813
Authors: David Maintz; Harald Seifarth; Rainer Raupach; Thomas Flohr; Michael Rink; Torsten Sommer; Murat Ozgün; Walter Heindel; Roman Fischbach Journal: Eur Radiol Date: 2005-12-07 Impact factor: 5.315
Authors: A A Dawkins; A L Evans; J Wattam; C A J Romanowski; D J A Connolly; T J Hodgson; S C Coley Journal: Neuroradiology Date: 2007-06-27 Impact factor: 2.804
Authors: Andreas M J Frölich; Sara M Pilgram-Pastor; Marios N Psychogios; Alexander Mohr; Michael Knauth Journal: Neuroradiology Date: 2010-08-19 Impact factor: 2.804
Authors: Gitsios Gitsioudis; Philipp Fortner; Matthias Stuber; Anna Missiou; Florian Andre; Oliver J Müller; Hugo A Katus; Grigorios Korosoglou Journal: Int J Cardiovasc Imaging Date: 2016-08-17 Impact factor: 2.357
Authors: R Syha; D Ketelsen; M Kaempf; S Mangold; S Sixt; T Zeller; F Springer; F Schick; C D Claussen; K Brechtel Journal: Eur Radiol Date: 2012-08-17 Impact factor: 5.315